GENERAL INFORMATION

GENERAL INFORMATION

IMPORTANT NOTES FOR BURNER INSTALLATION

Before fixing the burner to the boiler, make sure that:

 

− The door opens the right way (see the relevant sections 

for details on how to reverse the door)

 

− The length (L) of the burner fixing bolts is less than (S), 

i.e. the total depth of the seal, plates and washer. 

Longer 

bolts  can  cause  the  door  to  warp,  compromising  its 

ability  to  seal  the  boiler  hermetically  and  permitting 

the release of combustion fumes.

To ensure correct burner installation, also refer to the burner’s 

own manual.

L < S

S

L

If you are installing a new boiler but re-using an old burner, 

always perform the following checks:

 

− Make sure that the performance of the old burner is ad-

equate for the requirements of the boiler

 

− Make sure that the length and diameter of the burner 

nozzle are as specified in the following table.

 

9

When you finish installing the burner in the boiler, fill the 

gap between the burner’s blast tube and the refractory ma-

terial in the door with the ceramic insulation (A) supplied 

with the boiler.

A

Ø

L

TAU N

115

150

210

270

350

450

Burner head

L min. (mm)

110

110

170

180

180

195

Hole in door

Ø (mm)

162

162

162

180

180

210

TAU N

600

800

1000

1150

1250

1450

Burner head

L min. (mm)

200

200

200

200

200

205

Hole in door

Ø (mm)

210

235

235

230

230

265

 

0

Do not re-use old burners if their blast tube lengths are be-

low those specified in the table.

1.6 

Identification

The products are identified by:

Serial number plate

This is located on the boiler body and specifies the serial num-

ber, model, and furnace power.

Data plate

This  lists  the  technical  specifications  and  performance  of  the 

product. It comes inside the documentation envelope. On com-

pletion of the installation you MUST apply it in a clearly visible 

position at the top of one of the side panels. If you damage 

or lose this label, order a replacement immediately from 

R

's 

Technical Assistance Service.

 

9

If these plates or any other means of clearly identifying the 

product are defaced, removed or lost, proper installation 

and servicing may be rendered difficult.

23

27

0000581

WEEK OF 

MANUFACTURE

CALDAIA IN ACCIAIO

Modello

Matricola

Codice

Code

Anno fabbricazione

Tipo

Type

Portata term.

Pot. utile

Pres. Max esercizio

Aliment. elettrica

kW

T°Max ammessa

Contenuto acqua

°C

l

Combustibile utilizzato : TUTTI I GAS / GASOLIO

max (Hi)

Q

max

 60°/80°

P

PMS

Pressione focolare

kW

pn

PER CATEGORIA COMBUSTIBILE

E PAESI DI DESTINAZIONE

VEDI ETICHETTA BRUCIATORE

Portata term.

min (Hi)

Q

kW

Pot. utile

kW

T

max

Superficie di scambio

mbar

RIELLO S.p.A.

Via Ing.Pilade Riello 7

37045 Legnago (VR) - ITALY

066940IE

STEEL BOILER

Model

Serial number
Codice PIN

PIN number

Year of manufacture

Max. heat input

Min. heat input

Furnace pressure

Max. operating

 pressure

Max permitted

Max. useful

heat output

 60°/80°

P

min

heat output

Min. useful

Water capacity

Heat exchange

surface area

VEDI QUADRO ELETTRICO - SEE ELECTRIC CONTROL PANEL

Collegamento di terra obbligatorio - Obligatory ground connection

                     

  Fuel  

    : GAS / OIL

FOR FUEL TYPE COUNTRY

OF DESTINATION

SEE BURNER DATA PLATE

Power supply

  Pa

k

Matricola

Modello

Pres. Max esercizio

Portata term.

Q

max (Hi)

PMS

kW

RIELLO S.p.A.

Via Ing.Pilade Riello 7

37045 Legnago (VR) - ITALY

Serial no.

Model

Max.operating press.

Max. heat inpt

COMBUSTIBILE UTILIZZATO / FUEL: GAS, GASOLIO / GAS, OIL 

  Pa

k

Содержание TAU 1000 N

Страница 1: ...cod Doc 0053772 rev 39 04 2018 TAU 115 1450 N EN INSTRUCTIONS FOR THE SYSTEM MANAGER INSTALLER AND THE TECHNICAL ASSISTANCE SERVICE...

Страница 2: ...rt in the home for many years to come Arrange for your boiler to be serviced regularly by an authorised Technical Assistance Service R Their personnel are specially trained to keep your boiler efficie...

Страница 3: ...Putting into service 14 2 2 Preparing for extended periods of disuse 15 2 3 Cleaning 15 2 4 Maintenance 15 2 5 Useful information 16 3 INSTALLER 17 3 1 Unpacking the product 17 3 2 Overall dimensions...

Страница 4: ...must ALWAYS accompany the boiler even if it is sold to another owner or transferred to another user or to another installation If you damage or lose this manual order a replacement immediately from y...

Страница 5: ...for a smoother burner action and high temperature resistant stainless steel turbulators inside the tube bundle for maximum burner efficiency The boiler body is thoroughly insulated with a layer of hig...

Страница 6: ...for central heating 1 direct zone and 2 mixed zones and domestic hot water production with a single stage two stage or modulating burner Also for controlling solar heat ing system and cascaded boiler...

Страница 7: ...R RS 35 M BLU TC FS1 3910610 x R RS 25 E BLU TC FS1 3910710 x x RS 35 E BLU TC FS1 3910810 x RS 45 E BLU TC FS1 3897332 x R Reference burner used during performance qualification tests to derive the t...

Страница 8: ...7 1 7 1 7 1 5 1 5 Losses from casing with burner on 0 3 0 3 0 3 0 5 1 0 Constant pressure drop 300 300 420 540 700 W Flue gas temperature T 45 75 C Emissions at max heat input Nox 0 O2 80 mg kWh Flue...

Страница 9: ...9111 RX 360 S PV GPL 20137485 x 20029111 RX 500 S PV 20136698 x R 20029111 R Reference burner used during performance qualification tests to derive the technical data declared NOTE burners must be fit...

Страница 10: ...Constant pressure drop 300 300 420 540 700 W Flue gas temperature T 45 75 C Emissions at max heat input Nox 0 O2 70 60 mg kWh Emissions at max heat input CO 0 mg kWh Flue gas mass flow rate Qmax 0 05...

Страница 11: ...4031188 RS 68 E BLU TC FS1 3897432 x x 4031196 RS 120 E BLU TC FS1 3897632 x 4031196 RS 120 E BLU TC FS1 3897632 x 4031196 RS 160 E BLU TC FS1 3788032 x x 20047680 RS 160 E BLU TC FS1 3788032 x RS 50...

Страница 12: ...7 97 9 108 7 97 9 108 7 97 9 108 7 97 9 108 7 97 9 108 7 Losses from stack for sensible heat Qmax 1 9 Losses from casing with burner on 0 6 Constant pressure drop 0 2 Flue gas temperature T 45 75 C Fl...

Страница 13: ...d furnace power Data plate This lists the technical specifications and performance of the product It comes inside the documentation envelope On com pletion of the installation you MUST apply it in a c...

Страница 14: ...ust the timer thermostat if installed or the tempera ture control to the desired temperature 20 C Turn the boiler s mains power switch ON Turn the control panel power switch ON and make sure that the...

Страница 15: ...gents 0 0Never clean the boilerwithout first disconnecting it from the mains electricity supply by turning the mains power switch and the control panel switch OFF 9 9The combustion chamber and flue pi...

Страница 16: ...information Seller Mr Address Tel Technical Assistance Service Mr Address Tel Installer Mr Address Tel Date Work done Fuel oil supplier Mr Address Tel Date Quantity supplied Date Quantity supplied Da...

Страница 17: ...pletion of the installation Hydraulic test certificate Bar code labels Ceramic insulation B Cleaning brush C 9 9The instruction manuals are an integral part of the boiler therefore we recommend to rea...

Страница 18: ...315 1450 1450 1630 1630 1910 1910 2030 2030 2180 mm H1 Boiler height 1300 1300 1300 1437 1437 1615 1615 1900 1900 2015 2015 2167 mm D Height of burner plate 925 925 925 1030 1030 1235 1235 1390 1390 1...

Страница 19: ...to standards NBN D51 003 NBN D30 003 NBN B61 002 heat output 70 kW and NBN B61 001 heat output 70 kW 9 9When installing the boiler allow sufficient space around it to access all safety and control de...

Страница 20: ...put into service either contemporarily or with a very low rotation time during the initial period of service so as to evenly dis tribute the limited quantity of initial lime scale 9 9A flushing cycle...

Страница 21: ...opping up with fresh water To eliminate contact between air and water and to prevent the latter from becoming oxidized it is necessary For the expansion system to be a closed vessel type cor rectly sc...

Страница 22: ...e following table TAU N 115 1250 models M M 7 6 5 H A N B 8 F E D C 2 3 4 1 76 I G L O TAU N 1450 model M M 7 2 6 5 H I F 1370 G L O A N B E D C 2 8 3 4 1 9 9The choice of system components and the me...

Страница 23: ...5 885 885 1050 1235 1400 1600 1800 2050 2200 2200 2585 mm C Distance between heating returns 1 2 200 200 200 300 250 250 300 350 350 350 350 735 mm D Distance between heating return 2 and safety devic...

Страница 24: ...5 3 3 2 3 4 5 3 3 2 3 17 18 19 19 21 3 20 3 3 2 1 1 Boiler R TAU N 2 Central heating system manifolds 3 Disconnect valves 4 System pumps 5 Non return valves 6 Automatic vent valve 7 Boiler safety valv...

Страница 25: ...line with the top fitting H2 O L 3 8 Neutralising the condensate NEUTRALISATION KIT N2 N3 N2 N3 neutralisation units are designed for systems with boiler condensate drain pits located at a lower leve...

Страница 26: ...to the boiler condensate drain fitting using the flexible hose C supplied This condensate drain hose is specially made to prevent combustion fumes escaping into the atmosphere The outlet fitting B of...

Страница 27: ...ated flues are potentially dangerous and can cause burns 9 9If plastic flue gas outlet ducts are used install an O ring safety thermostat set to 90 C Install the thermostat on the flue gas outlet with...

Страница 28: ...nd two hinge fixing nuts System B on the larger sizes comes with a hinge fixing plate a nut and an internal compression spring A B A Smaller sizes system A Larger sizes system B Axis of door rotation...

Страница 29: ...upported by compression against the packing Remove the plug 1 taking care not to lose the compressed spring inserted in the threaded tube 2 3 4 2 3 6 6 5 6 5 6 4 4 4 Remove the bolt 3 and the nuts 4 R...

Страница 30: ...d as follows Unscrew the nut and washer 1 from the earth terminal Attach the earth cable s eye connector 2 to the terminal Make sure that the cable is of adequate size and com plies with legislation i...

Страница 31: ...casing using the screws provided The front side panels 2 and 3 and rear side panels 4 and 5 over the boiler frame 1 and to the top side beams On models 450 N NC 600 N NC 800 N 1000 N 1150 N 1250 N 145...

Страница 32: ...ly bled The condensate discharge siphon has been filled with water The mains power connections to the boiler and its ac cessories burner pump control panel thermostats etc have been properly made 9 9T...

Страница 33: ...en Set the boiler thermostat to the required setting making sure that the temperature control is in manual mode The control panel is switched OFF Set the room thermostat or timer to the required tem p...

Страница 34: ...System A Fit the door and tighten the main fixing bolts 1 until the seals start to compress Loosen the safety bolts 1 then fully screw in the main door fixing bolts 2 Make sure that the door is prope...

Страница 35: ...pection door 4 If more thorough cleaning is required remove the outer panels unscrew the eight fixing bolts and pull firmly on the flue gas box 5 to remove it from the boiler Check at regular interval...

Страница 36: ...Air in the circuit Check the circuit pressure Check the vent valve The generator is at temperature but the heating system is cold Air in the circuit Bleed the circuit Pump malfunctioning Check unseize...

Страница 37: ...37 TECHNICAL ASSISTANCE SERVICE TECHNICAL ASSISTANCE SERVICE...

Страница 38: ...38 TECHNICAL ASSISTANCE SERVICE TECHNICAL ASSISTANCE SERVICE...

Страница 39: ...39 TECHNICAL ASSISTANCE SERVICE TECHNICAL ASSISTANCE SERVICE...

Страница 40: ...lo 7 37045 Legnago VR www riello com The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liabl...

Отзывы: