Notes on safety for the installation
After carefully cleaning all around the area where the burner will
be installed, and arranging the correct lighting of the environ-
ment, proceed with the installation operations.
All the installation, maintenance and disassembly op-
erations must be carried out with the electricity sup-
ply disconnected.
The installation of the burner must be carried out by
qualified personnel, as indicated in this manual and
in compliance with the standards and regulations of
the laws in force.
4.2
Handling
The packaging of the burner includes a wooden platform, so it is
possible to move the burner (still packaged) with a transpallet
truck or fork lift truck.
With regard to the transport in the obligatory passages, refer to
the overall dimensions shown in Fig. 2.
The handling operations for the burner can be highly
dangerous if not carried out with the greatest atten-
tion: keep any unauthorised people at a distance;
check the integrity and suitableness of the available
means of handling.
Check also that the area in which you are working is empty and
that there is an adequate escape area (i.e. a free, safe area to
which you can quickly move if the burner should fall).
During the handling, keep the load at not more than 10” from the
ground.
After positioning the burner near the installation
point, correctly dispose of all residual packaging,
separating the various types of material.
Before proceeding with the installation operations,
carefully clean all around the area where the burner
will be installed.
4.3
Preliminary checks
Checking the consignment
After removing all the packaging, check the integrity
of the contents. In the event of doubt, do not use the
burner; contact the supplier.
The packaging elements (wooden cage or cardboard
box, nails, clips, plastic bags, etc.) must not be aban-
doned as they are potential sources of danger and
pollution; they should be collected and disposed of in
the appropriate places.
The output of the burner must be within the boiler's
firing rate;
A burner label that has been tampered with, removed
or is missing, along with anything else that prevents
the definite identification of the burner makes any in-
stallation or maintenance work difficult.
4.4
Operation position
The burner is designed to operate only in the positions
1
,
2, 3
and
4
Installation
1
is preferable, as it is the only one that allows the
maintenance operations as described in this manual. Installa-
tions
2
,
3 and 4
permit operation but make maintenance and in-
spection of the combustion head more difficult.
Any other position could compromise the correct operation of
the appliance.