31
When there is an operating fault a
flashing code is shown on the display
and the red led comes on in the event
of a definitive lockout.
For a description of the faults, refer to
the table below.
Resetting the faults
Wait about 10 seconds before resetting
normal operation conditions.
Then proceed as follows:
1) Display of the flashing alarm code
If just the flashing alarm is displayed
it means that a temporary stop was
diagnosed, if the fault is reset the
Display and fault codes
CODE DESCRIPTION OF TYPE OF
LOCKOUT
AL10
NUMBER OF IGNITION ATTEMPTS EXCEEDED (FLAME ABSENT/
CONDENSATION PRESENT)
LOCKOUT
AL20 LIMIT THERMOSTAT FAULT
LOCKOUT
AL21
LOW TEMPERATURE THERMOSTAT/CONDENSATION PUMP
SAFETY FAULT
LOCKOUT
AL26 RETURN LINE OVERTEMPERATURE
LOCKOUT
AL28 RETURN LINE/OUTLET PROBE DIFFERENTIAL FAULT
LOCKOUT
AL29 FLUE GASES PROBE OVERTEMPERATURE
LOCKOUT
AL34 TACKO FAN FAULT
LOCKOUT
AL40 SYSTEM WATER PRESSURE LOW (AFTER 10 MINUTES)
LOCKOUT
AL41
SYSTEM WATER PRESSURE LOW
STOP
AL52
GENERAL ELECTRONIC FAULT
LOCKOUT
AL55 FAULT DUE TO ABSENCE OF BOILER MODE CONFIGURATION
(CORRESPONDING JUMPER ABSENT)
LOCKOUT
AL60 DOMESTIC HOT WATER PROBE FAULT/WATER TANK PROBE
FAULT (IS i model)
SEE DEDICATED
PART
AL71
OUTLET PROBE FAULT (OPEN/SHORT CIRCUIT)
STOP
AL73
RETURN LINE PROBE FAULT (OPEN/SHORT CIRCUIT)
STOP
AL79 OUTLET OVERTEMPERATURE/ RETURN LINE/OUTLET PROBE
DIFFERENTIAL FAULT
LOCKOUT
AL91
PRIMARY HEAT EXCHANGER CLEANING (CALL CUSTOMER SER-
VICE)
SIGNAL
Faults and solutions