Electrical system
7.2
Electrical wiring
TESTING:
Check the shut-down of the burner by opening the thermostats
and the lock-out by darkening the photoresistance.
7.2.1
Control box
To remove the control box (Fig. 16) from the burner follow of the
istruction:
➤
Loosen the screw 1), open the protection 2) and remove all
components.
➤
Remove the coil 3).
➤
Loosen the two screws 4).
➤
Move a little the control box and remove the high voltage
leads.
WARNING
➤
Do not swap neutral and phase over, follow
the diagram shown carefully and carry out a
good earth connection.
➤
The electrical wiring carried out by the
installer must be in compliance with the rules
in force in the country.
➤
The section of the conductors must be at
least 1mm
2
. (Unless requested otherwise by
local standards and legislation).
Fig. 15
Capacitor
L
N
~
50Hz - 230V
Limit thermostat
Valve
D4240
CONTROL BOX
Photoresistance
535SE/LD
Safety thermostat
Motor
Remote lock-out signal
(230V - 0.5A max.)
Main switch
T6A
Blue
White
Black
PE
Ignition
electrodes
Burner-earth
DANGER
This operation must be performed with the burner
turned off and mains power disconnected.
Fig. 16
E9154
4
4
3
1
2
Содержание RDB3 CF 489T50