5906
2
DIMENSIONS (mm)
* It is possible with a spacer upon request.
OPERATION AND EFFICIENCY OF THE BURNER
ACCESSOIRES
RADIO DISTURBANCE PROTECTION KIT: Code 3010386
If the burner is installed in places particularly subject to radio disturbance (emission of signals exceeding 10 V/m) owing
to the presence of an INVERTER, or in applications where the length of the thermostat connections exceeds 20 metres,
a protection kit is available as an interface between the control box and the burner.
1
st
STAGE
POWER AND OUTPUT
MINIMUM
MAXIMUM
kW
kg/h
kW
kg/h
1
st
nozzle: ignition phase
391
33
782
66
1
st
+ 2
nd
nozzle: intermediate phase
794
67
1576
133
1
st
+ 2
nd
+ 3
rd
nozzle: operation phase
1186
100
2372
200
2
nd
STAGE
POWER AND OUTPUT
MINIMUM
MAXIMUM
kW
kg/h
kW
kg/h
1
st
nozzle: ignition phase
391
33
782
66
1
st
+ 2
nd
nozzle: 1
st
stage of operation
794
67
1576
33
1
st
+ 2
nd
+ 3
rd
nozzle: 2
nd
stage of operation
1186
100
2372
200
3
rd
STAGE
POWER AND OUTPUT
MINIMUM
MAXIMUM
kW
kg/h
kW
kg/h
1
st
nozzle: 1
st
stage of operation
557
47
794
67
1
st
+ 2
nd
nozzle: 2
nd
stage of operation
1067
90
1576
133
1
st
+ 2
nd
+ 3
rd
nozzle: 3
rd
stage of operation
1186
100
2372
200
Boiler front plate
drilling
Burner