![Riello CSV 25 R Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/riello/csv-25-r/csv-25-r_installation-instructions-manual_1460090009.webp)
GENERAL
9
COLLECTORS CONNECTION
The diagram below illustrates the connections between solar collectors in lines.
The fittings are available as accessories to be ordered separately.
The collectors in a line are connected so that the heat transfer fluid goes through them in series.
It is also possible to connect more then one line of solar collectors both in series (max 6 collectors in series) or in paral-
lel. Anyway the circuit must be hydraulically balanced (see the following schemes as an example).
collector
temperature sensor
to heat
exchange circuit
from heat
exchange circuit
union
olive
olive
ring nut
ring nut
union
olive
olive
ring nut
union
olive
olive
ring nut
stub pipe
stub pipe
stub pipe
T
T
Two lines in series
Two lines in parallel
b
These specifications are purely indicative. The entire structure must be inspected by an expert in static loading in
compliance with applicable standards.
Installation
height
above
ground (m)
Site’s wind
exposure
Mass in kg to secure collector
against lifting by wind
Altitude
(m.a.s.l.)
Total load on roof from wind and
snow loads and collector weight
(kg)
At angle of 45°
At angle of 20°
At angle of 45°
At angle of 20°
CSV 35 R
0-10
low
90
80
100
599
771
10-20
low
110
100
250
841
1093
0-10
medium
110
100
100
561
720
10-20
medium
130
120
250
753
976