USE

2 USE

2.1  Initial settings

The remote control was designed to ensure user-friendliness 
even with no special programming.
To activate, just install batteries and set current time.

Battery insertion

The remote control is powered by two AAA batteries (1.5 V) housed 
at the back, under a cover.
Should you notice a poorer reception or if display information 
fades out, the batteries must be changed.
To fit or change batteries:

 

remove the cover by pressing it down and lifting it up

 

if present, remove old batteries

 

fit new batteries according to proper polarity

Two 1.5V AAA batteries are supplied with the unit for its first 
set-up.

Never mix and match new and old batteries or different 
types of batteries.

When you remove the batteries, all settings in the remote 
control will be deleted. Fit the new batteries and reprogram.

Do not dispose of old batteries in the environment. Always 
take them to the suitable containers at points of sale.

time setting

The current time must be set before using the remote control:

 

open the door

 

press 

 

work on 

 

select the current time

Each time the key is pressed, the values changes by 1. by keeping 
the key pressed down, the value changes faster.

 

confirm with 

2.2 Start-up

To switch on:

ON 

OFF 

 

position the system's main switch in the "ON" position.

 

press 

The unit display turns on.

Use the remote control within a range of 7 meters, pointing 
it towards the receiver and making sure that there are no 
obstacles interposed.

The working range could be reduced if electronic starters or 
TV sets are nearby.

Do not leave the remote control exposed to direct sunlight, 
near sources of heat and protect it from water and dust.

The remote control is equipped with 1.5 V AAA batteries that 
must be removed when climate control system is left un-
used for over 3 months.

Содержание AARIA PRO AMC P

Страница 1: ...cod Doc 0093316 rev 1 06 2019 Remote control AMK P AMS P AMC P EN USER INSTRUCTIONS...

Страница 2: ...rective 2014 30 EU RoHS Directive 2011 65 EU ErP Directive 2009 125 EC and Regulation 2012 206 EC WEEE Directive 2012 19 EU F Gas Regulation 2014 517 EU Dear customer Thank you for choosing a R produc...

Страница 3: ...n p 8 1 6 4 Layout p 8 Unit display p 8 1 7 Remote control p 9 Function keys p 9 Remote control display p 10 2 USE p 11 2 1 Initial settings p 11 Battery insertion p 11 Time setting p 11 2 2 Start up...

Страница 4: ...le object spray cans within a 1 metre radius from the air expulsion 9 According to EU Regulation no 517 2014 regarding certain fluorinated greenhouse gases the total amount of refrig erant contained w...

Страница 5: ...or unit and regulate the room temperature 9 Safety device replacement must be carried out by R Technical Support Service using only original components Please refer to the spare parts catalogue 0 0 IT...

Страница 6: ...d to the operating mode room air temperature sensor transmitting the detected value to the control panel in order to control the operation of the outdoor unit and regulate the room temperature 9 Safet...

Страница 7: ...in combination with the outdoor unit The multiple speed fan DC motor im proves performance and sound comfort 1 6 2 Safety and adjustment devices The device safety and setting are achieved thanks to he...

Страница 8: ...dentification plates will not allow the product to be properly identified by its serial number 1 6 4 Layout 1 Condensation discharge 2 Refrigerant connections 3 Electrical box 4 Heat exchanger 5 Front...

Страница 9: ...ilable Select required ventilation speed minimum medium maximum or automatic Function not available DOOR OPEN 1 Door 2 Advanced function keys 2 1 When the door is open you can access the advanced func...

Страница 10: ...bo function enabled Quiet function enabled Economy function enabled Not available Timer settings Timer setting value or current time display Switch on timer enabled Switch off timer enabled Functions...

Страница 11: ...new batteries and reprogram 9 Do not dispose of old batteries in the environment Always take them to the suitable containers at points of sale Time setting The current time must be set before using t...

Страница 12: ...Value is stored with no need to press other buttons Switch off select another operating mode Alternatively press to deactivate Heating Mode The Heating mode allows starting and use of the air conditio...

Страница 13: ...ode Alternatively press to deactivate Adjusting ventilation speed Ventilation speed can be adjusted in the following modes Cooling Heating Dehumidification Ventilation Set required ventilation speed a...

Страница 14: ...tal air flow by setting a preferred outlet tilt or activating automatic opera tion not available on AMW ST Set required deflector position as follows A Initial position A work on select required posit...

Страница 15: ...Sleep function Sleep function is setting on 8 hour and cannot be modified Not actionable in FAN mode 9 In Smart mode depending on the operating mode selected by the programme 9 In the Sleep function f...

Страница 16: ...ent OFF time 9 Before activation set current time Activation press The display shows the and the time previously set Set required time as follows work on Each time the key is pressed the values change...

Страница 17: ...e control ON OFF position the system s main switch in the OFF position 2 7 Maintenance Routine maintenance is fundamental for keeping the equip ment efficient safe and reliable It can be performed per...

Страница 18: ...he mesh filter by grabbing the relevant fins remove dust with an vacuum cleaner repeat for all elements 9 Stubborn dirt can be removed by washing the filter in a luke warm max 40 C solution of water a...

Страница 19: ...rms AMK P In the presence of operating abnormalities the unit is secured and blocked 9 Safety block can occur randomly 9 Wait for at least 10 minutes before restarting the unit 9 If the fault occurs a...

Страница 20: ...wrong 14 E14 Fan motor malfunction Outdoor unit faults 9 Refer to the matching outdoor unit instruction booklet for the installer AMC P In the presence of operating abnormalities the unit is secured a...

Страница 21: ...e noise is heard during operation the circuit breaker a fuse or the circuit breaker circuit breaker trips continuously a switch or a button is not operating properly user smells burnt water leaks from...

Страница 22: ...disposal 3 DISPOSAL Packing materials must be disposed of separately in order to be recovered and recycled Equipment at end of life and flat bat teries must be disposed of as required by prevailing la...

Страница 23: ......

Страница 24: ...39 0442 630111 fax 39 0442 630371 www riello it As the manufacturer is constantly improving its products the aesthetic or dimensional features the technical data the equipment and accessories indicat...

Отзывы: