background image

co

d

. 2

0

0

15

0

9

6  r

e

v.

 1

1

0

9/

17

7200 Kombisolar 3S

EN

  INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Содержание 7200 KOMBISOLAR 1000 3S

Страница 1: ...cod 20015096 rev 11 09 17 7200 Kombisolar 3S EN INSTALLATION OPERATION AND MAINTENANCE MANUAL...

Страница 2: ...2 MODEL CODE 7200 KOMBISOLAR 430 3S 20010131 7200 KOMBISOLAR 550 3S 20010138 7200 KOMBISOLAR 750 3S 20010139 7200 KOMBISOLAR 1000 3S 20010140 RANGE...

Страница 3: ...tructions and precautions that must be observed to ensure the trouble free installation and efficient functioning of your r 7200 Kombisolar 3S com bination storage cylinder Please accept our renewed t...

Страница 4: ...description 6 Identification 6 Design 7 Technical specifications 8 Accessories 12 Water circuit 13 INSTALLATION 14 Unpacking the product 14 Dimensions and weight 14 Handling 15 Place of installation 1...

Страница 5: ...erfere with any control devices without specific authorisation and instructions from the manufacturer The operation of any appliance that uses electrical power and water demands that a number of funda...

Страница 6: ...67730ED COMBINATION STORAGE CYLINDER KOMBISPEICHER Model Modell Code Bestellnummer Serial number Seriennummer Year of manufacture Baujahr DHW coil capacity Inhalt der Warmwasserwendel Power absorbed b...

Страница 7: ...ket 8 Top coil 9 Storage cylinder temperature gauge 10 Domestic hot water outlet 11 DHW coil 12 Vent valve fitting 13 Inlet from boiler 14 Inlet from 2nd boiler 15 Central heating outlet 16 Return to...

Страница 8: ...ture gauge sensor socket diameter 1 2 M Top primary coil water capacity 7 1 8 0 10 0 10 0 l Bottom primary coil water capacity 11 0 12 8 17 4 19 8 l DHW coil water capacity 23 6 23 6 30 4 30 4 l Top p...

Страница 9: ...erature 80 C Performance achieved with boiler of suitable power configured for a flow rate of 1500 l h Description 7200 Kombisolar 3S 430 550 750 1000 Domestic hot water production 2300 2400 2600 2650...

Страница 10: ...mperature 80 C Performance achieved with boiler of suitable power configured for a flow rate of 3000 l h Description 7200 Kombisolar 3S 430 550 750 1000 Domestic hot water production 610 640 750 750 l...

Страница 11: ...op 7200 Kombisolar 3S BOTTOM COIL PRESSURE DROP mbar FLOW RATE l h 600 700 800 900 500 400 300 200 100 0 0 1000 2000 3000 4000 5000 6000 430 550 750 1000 PRESSURE DROP mbar FLOW RATE l h 600 700 800 9...

Страница 12: ...ntroller 4383382 RIELLO Solar MR water outlet and return kit 4383386 RIELLO Solar MR 25 70 water outlet and return kit 20011545 1 curved union kit for storage cylinder connection 4383171 Single phase...

Страница 13: ...recommended solar heating circuit flow rate see the installation instructions for the water outlet and return kit UAC Domestic hot water outlet EAF Domestic cold water inlet RE Sleeve for electric hea...

Страница 14: ...ckage consisting of a triple wall cardboard box 7200 Kombisolar 3S 430 550 or a plastic bag 7200 Kombisolar 3S 750 1000 on a wooden pallet The following items are delivered in a plastic bag inside the...

Страница 15: ...s able to support the weight of the storage cylinder Carefully rotate and slide the storage cylinder off the pallet on to the platform Make sure that the storage cylinder is perfectly stable and then...

Страница 16: ...on shells 6 Reverse the above steps to fit the insulation again b Make sure that the insulation shells 7 are securely fixed in place by straps before fitting the plastic cover Use a strap wrench if ne...

Страница 17: ...ndards Make sure that the circuit has been flushed out to remo ve all sludge and lime scale and has been vented and seal tested Make sure that a suitable water treatment system is installed if the qua...

Страница 18: ...n be connected to even previously installed hot water gene rators provided they are of adequate output power but care must be taken to ensure correct water flow directions They can also be easily inte...

Страница 19: ...bisolar 3S 5 Riello Thermoidro 6 Water treatment unit 7 Electronic pump 8 Riello Solar MR and expansion vessel 9 Room thermostat 10 Distribution manifold 11 Two way valve 12 Thermostatic mixer valve 1...

Страница 20: ...caping from the safety valve b Use a thermostatic mixer valve to limit the domestic hot water outlet temperature b If the pressure in the solar heating circuit drops do NOT top up with water but use t...

Страница 21: ...r socket 8 mm SRS Solar controller temperature sensor socket 16 mm It is essential to perform the following checks before starting up or testing the functioning of the combination storage cylinder In...

Страница 22: ...struction manual for the controller Start up the boiler to provide auxiliary heating for the combination storage cylinder Once the system has been started up perform the fol lowing checks Solar heatin...

Страница 23: ...used for an extended period of time prepare it for shut down as follows Shut down the boiler as instructed in its own manual Turn the system s main power switch OFF Drain the solar water circuit Close...

Страница 24: ...ly to the storage cylinder s valve group and to any associated boiler OFF at the main switch and at the control panel Close the shut off cocks for the domestic hot water cir cuit Drain the storage cyl...

Страница 25: ...he heat generator or solar heating system The pump is malfunctioning There is lime scale or sludge in the tank Water temperature is low Check the setting and condition of the thermostat Check the pump...

Страница 26: ...o low Set a T of 8 10 C There is lime scale or sludge in the tank Check and clean as necessary The flow rate is too high Reduce pump speed and turn the flow rate adjustment screw on the valve group to...

Страница 27: ...GENERAL 27...

Страница 28: ...egnago VR www riello com Aangezien het Bedrijf zich voortdurend inzet voor het optimaliseren van de volledige productie zijn de esthetische en dimensionele kenmer ken de technische gegevens uitrusting...

Отзывы: