background image

10

GENERAL

GENERAL

7200 V Plus 800 - 1000

RE

UAC

(*)

ES

RC

US

EAF

(SB)

A

B

C

D

E

F

G

H

L

I

R

 

7200 V Plus

 storage cylinders can also be connected to previously installed water heating systems provided they are of adequate 

output power, but care must be taken to ensure correct water flow directions.

Water fittings have the following specifications:

DESCRIPTION

7200 V Plus

800

1000

UAC 

Domestic hot water outlet

1"1/4M

Ø

ES 

Heat exchanger inlet

1"1/4F

Ø

RC 

DHW recirculation

1"M

Ø

US 

Heat exchanger outlet

1"1/4F

Ø

EAF (SB) Domestic cold water inlet (storage cylinder drain)

1"1/4M

Ø

RE 

Sleeve for electric heating element (not supplied)

1"1/2F

Ø

A

1470

1695

mm

B

950

1020

mm

C

400

400

mm

D

75

75

mm

E

354

354

mm

F

824

909

mm

G

919

1019

mm

H

1125

1241

mm

I

1707

2032

mm

L (*)

1459

1695

mm

(*) 

Fitting (L) can be used as an alternative installation position for the first magnesium anode (in positions that are not 

particularly high).

We recommend that you install isolating valves in the outlet and return lines.

 

9

Check the efficiency of the seals when filling/refilling the storage cylinder.

Содержание 7200.1000 V PLUS

Страница 1: ...cod 08700190 rev 7 12 2016 7200 V Plus EN INSTALLATION OPERATION AND MAINTENANCE MANUAL...

Страница 2: ...authorised R service centre Their personnel are specially trained to keep your storage cylinder efficient and cheap to run R service centres also stock any original spare parts that might be required...

Страница 3: ...specifications 6 7 Water circuit 7 8 Location of sensors 8 9 Overall dimensions and water fittings 9 INSTALLER 10 Unpacking the product 11 11 Handling 11 12 Place of installation 13 13 Installation i...

Страница 4: ...he boiler connected to the storage cylinder as instructed in its own manual Switch the storage cylinder OFF at the control panel if fitted and at the mains power switch Drain the central heating circu...

Страница 5: ...ell Serial number Seriennummer Code Year of manufacture Baujahr Maximum absorbed power T Primary 80 C Max Leistungsaufnahme T Prim rkreis 80 C Operating pressure Betriebsdruck Power supply Stromversor...

Страница 6: ...ctric heating element not supplied 1 1 2 F Maximum power absorbed Primary coil at 80 C 50 2 80 7 92 6 92 6 93 8 114 kW Primary coil at 88 C 60 7 96 9 117 117 113 134 kW Coil water capacity 9 2 12 2 25...

Страница 7: ...e installed as standard in the vertical position to fitting 11 an expansion vessel safety system can be connected directly to the top flange Note The above schematic is purely indicative 9 9R 7200 V P...

Страница 8: ...nstallers must use their expertise to ensure proper installation and functioning in compliance with all applicable legislation Ps Bt Ps M Ps Socket for storage cylinder THERMOSTAT SENSOR or storage cy...

Страница 9: ...430 550 UAC Domestic hot water outlet 1 F ES Heat exchanger inlet 1 F 1 1 4F RC DHW recirculation 3 4 F US Heat exchanger outlet 1 F 1 1 4F EAF SB Domestic cold water inlet storage cylinder drain 1 F...

Страница 10: ...inlet 1 1 4F RC DHW recirculation 1 M US Heat exchanger outlet 1 1 4F EAF SB Domestic cold water inlet storage cylinder drain 1 1 4M RE Sleeve for electric heating element not supplied 1 1 2F A 1470...

Страница 11: ...certificate and barcode label Spare parts catalogue Hydraulic test certificate 4 adjustable feet 9 9The second anode for installation instead of the inspection flange is supplied separately and must...

Страница 12: ...since it can become a potential hazard Dispose of packaging material in compliance with applicable legislation MODELS 7200 V Plus 800 to 1000 Make sure that any lifting equipment is of adequate capaci...

Страница 13: ...V Plus storage cylinders can be installed in any room where there is no specific requirement for an electrical protection rating higher than IP X0D 0 4 m 0 6 m 0 3 m 0 4 m 9 9Respect the minimum speci...

Страница 14: ...its have been bled Turn the main power switch OFF and make sure that the water heating system shuts down completely Provided the above checks have been completed satisfactorily restart the system and...

Страница 15: ...cleaning product Dry the storage cylinder after cleaning it 0 0Do not use abrasive products petrol or triethylene INTERNAL CLEANING MODELS 7200 V Plus 200 to 550 Removing and checking the magnesium a...

Страница 16: ...suitable wrench to unscrew the anode holder 6 Check the magnesium anode for wear and replace it if necessary On completion of cleaning follow the above steps in the reverse order to refit all removed...

Страница 17: ...licable legislation 20 TROUBLESHOOTING FAULT CAUSE SOLUTION The storage cylinder functions incorrectly or irregularly Flow rate too high Fit a pressure limiter Fit a flow reducer There are blockages o...

Страница 18: ...will remain above ZERO simply adjust the storage cylinder s thermostat to its minimum temperature 9 9If outdoor temperature may drop below ZERO risk of freezing performtheoperationsdescribedinthe Prep...

Страница 19: ...19 END USER END USER...

Страница 20: ...el 0442630111 Fax 044222378 www riello it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore...

Отзывы: