MALFUNCTIONS

MALFUNCTIONS AND ERROR MESSAGES

If the controller detects a malfunction, the red LED blinks 

and the warning symbol appears on the display.

If the malfunction resolves itself, the warning symbol 

becomes an information symbol and the red LED stops 

blinking.

To view details of the error, press the key under the warn-

ing or information symbol.

 

b

End users must not attempt to resolve malfunctions 

in person. Always refer malfunctions to specialist 

personnel!

esc

(Flashing LED +

error message)

Possible error messages

Note for service personnel

Sensor x error

This means that there is/was a fault in the sensor, input to the controller or connecting 

cable.

Time & date

This message appears automatically after a power failure to indicate that the time 

and date must be checked and reset if necessary.

REPLACING THE FUSE

 

b

Replace the fuse with the one contained into the document envelope.

 

b

Repairs and maintenance may only be performed 

by a specialist. Before working on the unit, switch 

off the power supply and secure it against being 

switched on again! Check for the absence of power!

 

b

Only use the supplied spare fuse or a fuse of the 

same design with the following specifications: T2A 

250V

If the mains voltage is switched on and the controller still 

does not function or display anything, then the internal 

device fuse may be defective. In that case, open the de-

vice as described under 3.1, remove the old fuse and 

check it.

Exchange the defective fuse for a new one, locate the 

external source of the error (e.g. pump) and exchange 

it. Then first recommission the controller and check the 

function of the switch outputs in manual mode.

MAINTENANCE

 

b

In the course of the general annual maintenance of your heating system you should also have the functions of the 

controller checked by a specialist and have the settings optimised if necessary.

Performing maintenance:

• Check the date and time

• Assess/check plausibility of analyses

• Check the error memory

• Verify/check plausibility of the current measurement values

• Check the switch outputs/consumers in manual mode

• Poss. optimise the parameter settings

Fuse

Содержание 20182669

Страница 1: ...low primary temperature finds a wide use in thermal solar systems and in underfloor heating 3 way mixing valve estabilishes the inlet water temperature ideal function for the summer in which the syste...

Страница 2: ...roduct to the elements It is not designed for use outdoors ELECTRICAL CONNECTIONS The product must be installed and all electrical connections made by suitably qualified personnel in conformity to app...

Страница 3: ...y mixing valve type TV3 DN25 with electric actuator NRYC230 6 Ball valve DN25 with nut 1 7 Red handle 8 Blue handle 9 Load drain tap 10 Manual air vent valve 3 8 11 Electronic regulator mod LFWC 12 Vo...

Страница 4: ...sorbed with storage cylinder at 55 C and DHW water delivery at 10 45 C 146 kW Water draw at 10 45 C with storage cylinder at 55 C 60 l min Thermal power absorbed with storage cylinder at 60 C and DHW...

Страница 5: ...HARACTERISTIC CURVES FOR PRIMARY CIRCUIT PUMPS Q m3 h 0 1 2 3 4 1 2 3 4 5 6 7 8 9 10 11 12 H m Q l s Q lgpm 0 0 2 0 4 0 6 0 8 1 0 1 2 0 4 8 12 Q m3 h 0 1 2 3 4 20 40 60 80 100 120 P 1 W 140 160 2m 4m...

Страница 6: ...ONS AND FITTINGS 70 226 835 MP 80 75 100 475 100 EAFS UACS RP RS SC ACS 80 MP Primary inlet 1 F RP Primary outlet return 1 F EAFS Domestic cold water inlet 1 F UACS DHW outlet 1 F RS Recirculation uni...

Страница 7: ...ump BL Neutral line N primary pump Connect to controller terminal VFS1 Main voltages 230VAC 50 60Hz Connection on the right part of the terminal board b Main side 230 VAC Low voltage max 12VAC DC Conn...

Страница 8: ...bility ends with the supply of the product The product must be installed in conformity to applicable standards by suitably qualified persons employed by a company that assumes full responsibility for...

Страница 9: ...ng of the product b It is advisable to install the product as near as prac tically possible to the storage cylinder in order to avoid unnecessary heat loss from the connecting pipes INSTALLATION ON TH...

Страница 10: ...gs are assembled in the factory It is nevertheless advisable to check their tightness after installing the prod uct It is also necessary to test the product for water tight ness at operating pressure...

Страница 11: ...the primary circuit inlet and outlet ball valves Set the controller for operation in manual mode see parameter 3 2 Switch on the primary circuit pump Open the vent valve Pump water around the circuit...

Страница 12: ...rtinent EN standards and installation and operating instructions accompanying system components must also be observed Installation electrical connection setting and maintenance of the controller must...

Страница 13: ...with ordinary household refuse Dispose of the unit only at appropriate collection points or ship it back to the seller or manufacturer TECHNICAL SPECIFICATIONS Electrical specifications Voltage 100 2...

Страница 14: ...o be connected to the socket on the circuit board Sensor 2 Cold water If no sensor is connected a temperature of 10 C is set S5 S4 S3 S2 S1 R3 PELV R3I R2 R1 L N V1 CAN CAN VFS2 VFS1 V2 S6 Control cir...

Страница 15: ...lues scroll menu up down yes no confirm cancel Info additional information Back return to previous screen ok confirm selection Confirm confirm setting Finally accessing menu 3 2 and selecting Manual m...

Страница 16: ...essary for your application Free commissioning If you decide not to use the commissioning help you should make the necessary settings in the following sequence Menu 6 Special functions clock Additiona...

Страница 17: ...roller Please note that the clock continues to run for about 24 hours if the mains voltage is interrupted and after that has to be reset Improper operation or an incorrect time may result in data bein...

Страница 18: ...ety facilities to be provided by the customer To quit the menu press esc or select Exit settings 4 1 Tset Setpoint at VFS sensor The controller LFWC provides this hot water temperature tap temperature...

Страница 19: ...ti legionella With the AL function activated the LFWC makes it pos sible to heat the storage in selectable intervals AL interval for the set residence time AL resid time starting at the set time AL st...

Страница 20: ...pumps with 0 10V PWM pumps can be connected to the corresponding relay V1 R1 R2 V2 since the relays are switched on and off with the signal 6 1 1 Pump type This menu is used to set the type of pump a...

Страница 21: ...ing the defined heating times heating is activated 6 5 2 4 Switch off hysteresis for storage heating The storage target temperature is calculated from Tmin or Tset storage at the given operating time...

Страница 22: ...tart aid function With some solar systems especially with vacuum tube collectors it may occur that the measurement value acquisition at the collector sensor occurs too slowly or too inaccurately becau...

Страница 23: ...6 Pmax Max pressure If the pressure exceeds this value an error message is displayed and the LED links red 6 9 Sensor calibration Deviations in the temperature values displayed for example due to cabl...

Страница 24: ...e other menus select Menu lock ON To enable the menus again select Menu lock OFF 7 2 Expert mode This menu is used to switch between expert mode in which all settings are available and simple mode in...

Страница 25: ...ialist Before working on the unit switch off the power supply and secure it against being switched on again Check for the absence of power b Only use the supplied spare fuse or a fuse of the same desi...

Страница 26: ...imary de livery from 30 to 80 C 48 C 4 8 2 Max primary delivery from 30 to 80 C 65 C 4 8 3 Rotation time from 1 to 3 se conds 1 sec 4 8 4 Pause factor from 0 1 to 4 seconds 1 sec 4 8 5 Increase from 0...

Страница 27: ...ulation pump 6 3 1 Pump type 0 10V PWM PWMs 6 3 2 Pump Solar Recirculation 6 3 3 Output signal normal inverted Normal 6 3 4 PWM off 0 15 2 6 3 5 PWM on 2 50 13 6 3 6 PWM max 9 100 93 6 4 V2 Pump speed...

Страница 28: ...llo 7 37045 Legnago VR www riello com The manufacturer strives to continuously improve all products Appearance dimensions technical speci cations standard equipment and accessories are therefore liabl...

Отзывы: