TECHNICAL DATA

 

2.1

TECHNICAL DATA 

 

 

 

 

Light oil is not permitted on low level discharge of flue gas products.

 

2.2

OVERALL DIMENSIONS

2.3

FIRING RATES,

 

(as EN 267)

TYPE

483 T50

485 T50

501T2K

487 T50

 

Output   –   Thermal power

 

(with air at 20 °C)

 

kg/h

1.8 – 3.4

1.5 – 2.5

1.8 – 2.8

2.3 – 3.9

kW

21.6 – 40.6 

18 – 29.9

21.6 – 33.5

27.6 – 46.6

Fuel

Kerosene, viscosity 1.6 – 6 mm

 

2

 

/s at 20 °C

 

 

(Hi = 11.97 kWh/kg)

 

Light oil, viscosity

4 – 6 mm

 

2

 

/s at 20 °C

 

◆  

 

(Hi = 11.86 kWh/kg)

 

Electrical supply

Single phase,

 

~

 

 50Hz  230 V 

 

±

 

 10% 

Motor

Run current

0.7 A

2700 rpm

283 rad/s

Capacitor

4.5 

 

µ

 

F

Ignition transformer

Secondary

8 kV

16 mA

Pump

Kerosene,  maximum pressure 10 bar (145 psi)
Light oil,

 maximum pressure 15 bar (218 psi)

Absorbed electrical power

kW

0.115

0.125

Flange

Burner

140

A

202

130

20

45°

ø

 

B

223.5

11

168

D6114

180

72

72

150

45°

136

TYPE

A

Ø

 

B

483T50

96

90

485T50

90

84

501T2K

50

85

487T50

96

90

1.4

Pressure in the combustion

chamber – mbar

Fuel output - kg/h

Thermal power - kW

0.8

1.0

1.2

0.4

0.2

0.6

D4503

0

15

20

40

25

30

35

45

2

2.5

3

3.5

1.5

4

487T50

483T50

501T2K

485T50

Содержание 3513007

Страница 1: ...stallation use and maintenance instructions CODE MODEL TYPE 3748357 RDB1 70 90 483T50 3748557 RDB1 50 70 485T50 3513007 RDB1 WM 50 70 501T2K 3748757 RDB2 90 120 487T50 KEROSENE BURNER KEROSENE AND LIG...

Страница 2: ......

Страница 3: ...nt 7 4 2 Nozzles recommended 7 4 3 Electrodes setting 7 4 4 Pump pressure 7 4 5 Air damper adjustment 7 4 6 Burner start up cycle 8 5 MAINTENANCE 8 6 FAULTS SOLUTIONS 9 One stage kerosene and light oi...

Страница 4: ...C Hi 11 86 kWh kg Electrical supply Single phase 50Hz 230V 10 Motor Run current 0 7A 2700 rpm 283 rad s Capacitor 4 5 F Ignition transformer Secondary 8 kV 16 mA Pump Kerosene maximum pressure 10 bar...

Страница 5: ...N APPROPRIATE BF BOILER In case of BF applications an optional snorkel and gasket are availa ble replacing A with B This item can be supplied separately The combustion air supply is through a flexible...

Страница 6: ...st 80 mm The intake tube can be up to 6 metres in length Warning length is reduced if there are bends in the intake section For instance using a tube with a smooth inside surface you must allow for th...

Страница 7: ...s screw 4 Gauge connection 5 Pressure adjuster 6 Suction gauge connection 7 Valve 8 Auxiliary pressure test point PRIMING PUMP On the system in fig 5 it is sufficient to loosen the suction gauge conne...

Страница 8: ...4240 CONTROL BOX Photoresistance 535SE LD thermostat Safety thermostat Motor Remote lock out signal 230V 0 5A max Main switch T6A Blue White Black PE Ignition electrodes TESTING Check the shut down of...

Страница 9: ...kerosene working 10 bar maximum pressure for kerosene FOR LIGHT OIL INCREASE PRESSURE 12 bar pressure suitable for light oil in most cases 14 bar improves flame retention it is therefore suitable for...

Страница 10: ...re not obstructions or dents in the supply or return oil pipes Clean the filter in the oil suction line and in the pump Clean the photoresistance 8 fig 1 page 1 Check for correct fuel consumption Repl...

Страница 11: ...uction enclosed with the burner or due to the intervention of unqualified personnel FAULTS POSSIBLE CAUSES SOLUTION The burner will not start when the limit thermostat closes Lack of electrical supply...

Страница 12: ......

Отзывы: