Page 27 of 79
Technical Documentation and
User Instructions
Laser Mirror Scanner LMS-Q280i
4.5 Instrument Cooling
To enable appropriate heat dissipation by means of natural air convection, the
heat sink profiles must not be covered by objects which are located very closed
to the laser scanner. Operation at higher ambient temperature and/or reduced
air convection (low atmospheric pressure) could require additional forced
cooling (external fan). The housing surface temperature should not exceed
+40°C.
4.6 General System Set Up and Cabling
•
Provide a suitable power supply for the laser scanner (please refer to
chapter 4.1, Preparing the Power Supply).
•
Mount the laser scanner LMS-Q280i by means of the mounting threads.
•
Connect the LAN-TCP/IP interface or alternatively the parallel and the
serial interface of the instrument to a personal computer or equivalent
data acquisition unit using the LAN cable or the parallel and serial
connection cables.
•
Connect the instrument to the power supply using the power supply
cable.
After switching-on the power supply the scanner starts with
•
the “Laser setup and test procedure” (see chapter 4.7 for details),
and then
starts scanning automatically .