background image

Thermoport®

As per 07/2006

Subject to technical changes!

Page 1

For your safety:

These operating instructions contain important information about the use of the device. Please ensure that
all operators familiarise themselves with the contents. These operating instructions are also available in the
Internet at 

http://www.rieber.de/

 .

Warning! Danger! Electrical voltage
The electrical devices may only be used when fully functional. Always pull on the plug and never
on the power cable as this causes damage! Always pull the plug from the socket before moving
the device.
The mains plug must be accessible at all times in order to be able to disconnect the unit from
the mains supply in an emergency.
Before using the device, always check the mains plug and the power cable for visible damage.

Careful! Danger of burns!
Be careful when removing and loading GN containers or cooktainers; there is a danger of burns
on hot surfaces.

Therefore wear protective gloves!

2 Proper 

use:

The Thermoport 50KB- 1000KB is only designed for storing, heating and transporting warm food. The
Thermoport can hold GN containers of the size max. 1/1 and different depths.
The Thermoport® 50K/ 1000K is only designed for storing and transporting warm and/or cold food. The
Thermoport® can hold GN containers of the size max. 1/1 and different depths.
Maximum storage capacity 50K+ 50KB: 1x GN 1/1, 100 mm deep.
Maximum storage capacity 100K+ 100KB: 1x GN 1/1, 200 mm deep.
Maximum storage capacity 1000K+ 1000KB: 2x GN 1/1, 200 mm deep.

 

It is forbidden to equip the heated wells and/or the drawers or compartments with Gastronorm containers
that are made of non-heat-resistent or flammable material.

 

Never operate the device unsupervised.

 The 

Thermoport® may not be thrown.

 

Persons may not sit or stand on the Thermoport®.

3 Transport 

and 

positioning:

 

There is a carrying handle on the left and right of the Thermoport® for safe transportation.

 

Position the device horizontally, securely and stably.

 

Ensure that no-one can trip over the electrical cable.

 

The devices can be stacked. The runners on the base of the Thermoport® click into a moulded groove
on the lid of the next Thermoport®

 The 

Thermoport® should be stored at room temperature.

Operating Instructions

Plastic Thermoport®

Thermoport® 50K, 50KB, 100K, 100KB, 1000K, 1000KB

Содержание Thermoport 1000K

Страница 1: ...nd transporting warm food The Thermoport can hold GN containers of the size max 1 1 and different depths The Thermoport 50K 1000K is only designed for storing and transporting warm and or cold food The Thermoport can hold GN containers of the size max 1 1 and different depths Maximum storage capacity 50K 50KB 1x GN 1 1 100 mm deep Maximum storage capacity 100K 100KB 1x GN 1 1 200 mm deep Maximum s...

Страница 2: ...ith a closed lid Temperature range 20 C to 100 C Please also ensure that the GN containers you insert do not undercut or exceed these temperatures Warm food should be inserted at a minimum temperature of 85 C see HACCP rules The transportation and holding times should not exceed 2 hours see HACCP rules In the case of liquid food the GN containers should be closed with water tight press in lids To ...

Страница 3: ...l number 37130309 4 Runners Material number 37130401 1 2 3 4 1 Lid Material number 85022501 2 Insert card Material number 37190601 3 Complete handle Material number 37130309 4 Runners Material number 37130401 5 Heating element Material number 55050214 1 Lid Material number 85022501 2 Insert card Material number 37190601 3 Complete handle Material number 37130309 4 Runners Material number 37130401 ...

Страница 4: ...mber 37138909 6 Insert card Material number 37190601 1 Lid Material number 85022501 2 Insert card Material number 37190601 3 Complete handle Material number 37130309 4 Runners Material number 37130401 5 Heating element Material number 55050214 1 2 3 4 5 6 1 Doors Material number 85022519 2 Door catch Material number 37133202 3 Carrying handle Material number 37130306 4 Runners Material number 3713...

Страница 5: ...y friendly manner observe local regulations 11 Liability and warranty The terms and conditions of sale and delivery of the company Rieber GmbH Co KG that are valid on the invoice date apply to all warranty claims made to the manufacturer Excluded from the warranty All installed parts that are subject to consumption or natural or mechanical wear e g seals power cables tires corner bumpers bumpers N...

Отзывы: