Fault - What now?
28
Rieber GmbH & Co. KG
10
Fault - What now?
DANGER!
Danger of electric shock. Dangerous electrical voltage.
►
Disconnect the connecting plug on the unit before starting repair work.
►
Have all electrical repairs carried out by an authorised electrician only.
Fault
Possible cause
Possible remedy
Indicator lamp not on
Appliance not connected correctly
Check connection / plug
connectors.
#
User
No power supply
Check existing fuse.
#
Qualified electrician
Temperature not
controllable
Temperature controller defective
Replace
#
Qualified electrician
appliance has overheated
Built-in adjustment pipe
type ERRV-H …, ERE-H
or heated plate dispenser
gets too hot
Capillary tube of temperature
sensor is damaged.
Sensor not fixed correctly.
Do not touch or move the
appliance.
Disconnect appliance from
power supply, switch off circuit
breakers/fuses in switch box.
Replace
#
Qualified electrician
Plug / spiral cable / rocker
defective
Repair.
#
Qualified electrician
Casters / brakes blocked
Remove blocking foreign
bodies.
Release brake.
#
User
Casters / brakes defective
Replace caster
Replace
#
User
Indicator lit up but appliance
does not heat up
Overheating protection has tripped
Replace
#
Qualified electrician
Crockery does not move
down enough
Spring force too high
Remove springs.
#
User
Also see page 17
Crockery moves down too
Spring force too low
Install springs.