Fault – What now?
38
Rieber GmbH & Co. KG
9
Fault – What now?
# Notes on troubleshooting
Danger of electric shock. Dangerous electrical voltage.
Danger of electric shock. Dangerous electrical voltage.
►
Switch off and separate a damaged electrical appliance.
►
Have all electrical repairs carried out by an authorised electrician only.
Possibility of malfunction after power interruption.
Disconnect the unit from the mains
completely after a power failure. Then switch the appliance on again.
‘General mode of operation ’, page 20
Any repairs during warranty period may only be performed by manufacturer´s service department of
Rieber. Please contact the manufacturer´s service department of Rieber.
Fault
Possible cause
Rectification
Appliance does not heat up
If thermoplate
®
is missing from the
heating surface, the appliance
switches off with a time delay.
Restart process.
#
Operating staff
Page
20
Indicator light for operating
state does not come on
Is voltage present?
Do mains voltage and mains
frequency match the
information on the type plate?
Rocker switch switched ON?
#
Operating staff
Inadequate heating power
Appliance defective
Repair
#
Rieber Service
The casing is excessively
hot
Appliance defective
Repair
#
Rieber Service
Ceran
®
glass surface
damaged, for example crack
or break
Mechanical impact
Repair
#
Rieber Service
Connection line or
connector plug damaged
Mechanical impact; appliance
defective
Repair
#
Qualified electrician