
Ridge Tool Company
20
SeeSnake
®
Standard and Mini Pipe Inspection Systems
Camera video image not
seen.
Count accuracy seems
unreliable.
Low Battery warning
appears.
The symbol “+” appears
after the on-screen dis-
tance measurement.
No power to SeeSnake CCU connector.
Connections faulty.
Video Source incorrect.
Settings incorrect for reel or cable being used.
Counting from a zero point other than the one in-
tended.
Battery dead or near-dead.
Physical cable measurement has exceeded the
cable parameter in settings.
Check power is correctly plugged in.
Check switch on SeeSnake CCU.
Check alignment and pins of connection to CCU
or DVR unit from SeeSnake.
Check orientation, seating, and pin condition in the
SeeSnake connection.
Check CCU Video Source setting. See CCU
manual.
Verify the settings are correct for the SeeSnake
cable length, cable diameter and reel type you are
using.
Confirm you are measuring from the intended zero-
point.
Replace 3-volt battery in the Count
Plus (CR2450).
Verify the actual length of your installed cable; re-set
the reel and cable settings for the correct reel type
and actual cable length and diameter as described
on
page 14 or in your CountPlus manual.
PROBLEM
PROBABLE FAULT LOCATION
SOLUTION
Chart 1 Troubleshooting
www.
GlobalTestSupply
.com
Find Quality Products Online at: