DANGER:

GROUNDING THE GENERATOR

To reduce the risk of shock or electrocution, generator must be 
properly grounded. The nut and ground terminal on the frame 
must always be used to connect the generator to a suitable 
ground source. The ground path should be made with #8 size 
wire. Connect the terminal of the ground wire between the lock 
washer and the nut, and tighten the nut fully. Connect the other 
end of the wire securely to a suitable ground source.
The National Electric Code contains several practical ways in 
which to establish a good ground source. If a steel or iron rod is 
used, it should be at least 5/8 in. diameter, and if a nonferrous 
rod is used, it should be at least 1/2 in. diameter and be listed as 
material for grounding. Drive the rod or pipe to a depth of 8 ft. If 
a rock bottom is encountered less than 4 ft. down, bury the rod 
or pipe in a trench. 
All electrical tools and appliances operated from this generator 
must be properly grounded by use of a third wire or be “Double 
Insulated.”
It is recommended to:
1.  Use electrical devices with 3-prong grounded plugs.
2.  Use an extension cord with a 3-pole receptacle and a 3-prong plug at opposite ends to ensure continuity of the 
 

ground protection from the generator to the appliance.

Check and adhere to all applicable federal, state, and local regulations relating to grounding specifications. Consult a 
qualified electrician or service personnel if the grounding instructions are not completely understood or if in doubt as 
to whether the generator is properly grounded.

 

Introduction ..................................................................................................................................................................... 2

 

Important Safety Instructions .......................................................................................................................................3-4

 

Specific Safety Rules ...................................................................................................................................................... 4

 

Symbols .......................................................................................................................................................................5-7

 

Electrical .......................................................................................................................................................................7-9

 

Features  ........................................................................................................................................................................ 10

 

Assembly ..................................................................................................................................................................11-12

 

Operation ..................................................................................................................................................................13-15

 

Maintenance .............................................................................................................................................................16-18

 

Troubleshooting ............................................................................................................................................................. 19

 

Warranty ...................................................................................................................................................................20-22

 

Parts Ordering / Service ...................................................................................................................................Back Page

TABLE OF CONTENTS

INTRODUCTION

This product has many features for making its use more pleasant and enjoyable. Safety, performance, and dependability 
have been given top priority in the design of this product, making it easy to maintain and operate.

Содержание RD905712 Series

Страница 1: ...ado y fabricado de conformidad con nuestras estrictas normas para brindar fiabilidad facilidad de uso y seguridad para el operador Con el debido cuidado le brindar muchos a os de s lido funcionamiento...

Страница 2: ...eferenced in the operator s manual Consulter l encart volets afin d examiner toutes les figures mentionn es dans le manuel d utilisation Consulte esta secci n desplegable para ver todas las figuras a...

Страница 3: ...t AC GFCI 20 amp receptacles prises 120 V C A disjoncteur de fuite la terre 20 A 120 V de CA GFCI 20 A recept culos I 240 V AC 30 amp receptacle prise 240 V C A 30 A 240 V de CA 30 A recept culo J AC...

Страница 4: ...rubber foot pied avec patin en caoutchouc pata con pie de goma E Frame cadre armaz n Fig 3 1 Axle bolt essieu eje 2 Wheel roue rueda 3 Washer rondelle arandela 4 Lock nut crou de blocage tuerca de se...

Страница 5: ...GFCI receptacles prises 120 V C A 20 A disjoncteur de fuite la terre recept culos de 120 V de CA 20 A de GFCI C AC circuit breaker disjoncteur de C A disyuntor de circuito de CA D 240 volt AC 30 amp...

Страница 6: ...posici n apagado E Run position position de marche posici n de functionamiento F Choke lever levier de volet de d part palanca del anegador F E D A Screws vis tornillos B Airfiltercover couvercledufil...

Страница 7: ...ite C Oil drain plug huiler le bouchon d gout tap n de drenaje del aceite C C A Fuel line conduite de carburant conducto de combustible B Petcock petit robinet llave de purga C Fuel valve robinet de c...

Страница 8: ...operated from this generator must be properly grounded by use of a third wire or be Double Insulated It is recommended to 1 Use electrical devices with 3 prong grounded plugs 2 Use an extension cord...

Страница 9: ...tially enclosed area Breathing exhaust fumes will kill you Keep all bystanders children and pets at least 10 feet away Wear sturdy and dry shoes or boots Do not operate while barefoot Do not operate g...

Страница 10: ...l gas filling station Do not touch the muffler or cylinder during or immediately after use they are HOT and will cause burn injury This generator has a neutral bonded condition This means the system g...

Страница 11: ...sion can cause severe burns or death Hot Surface To reduce the risk of injury or damage avoid contact with any hot surface Lifting Hazard To reduce the risk of serious injury avoid attempting to lift...

Страница 12: ...las ventanas abiertas S lo util celo AL AIRE LIBRE y lejos de ventanas puertas y respiraderos Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a po...

Страница 13: ...ft 125 ft 75 ft 25 3000 6000 150 ft 100 ft 30 3600 7200 125 ft 65 ft 40 4800 9600 90 ft FUEL WARNING No smoking when filling with gasoline Do not overfill Full level is 1 in below the top of the fuel...

Страница 14: ...d cause the Reset button to pop out To restore power depress the RESET button Perform this test monthly to ensure proper operation of the GFCI If the generator is stored outdoors unprotected from the...

Страница 15: ...afe way to manage generator power is to sequentially add loads as follows 1 With nothing connected to the generator start the engine as described later in this manual 2 Plug in and turn on the first l...

Страница 16: ...the engine FUEL TANK The fuel tank has a capacity of 6 gallons FUEL VALVE The flow of fuel through the generator is controlled by the position of the fuel valve GenSmart MONITORING SYSTEM The GenSmar...

Страница 17: ...us personal injury Inspect the product carefully to make sure no damage occurred during shipping Do not discard the packing material until you have carefully inspected and satisfactorily operated the...

Страница 18: ...of the frame support The tab on the leg should face the inside of the generator frame Insert each 2 in screw through a washer and insert the screws through the two holes in the frame and the leg Faste...

Страница 19: ...nces tools and motor loads BEFORE OPERATING THE UNIT Only use OUTSIDE and far away from windows doors and vents NEVER use inside a home or garage EVEN IF doors and windows are open Always position the...

Страница 20: ...y from ignition sources handle outdoors only do not smoke while adding fuel and wipe up spills immediately OPERATION When adding gas to the generator make sure the unit is sitting on a flat level surf...