Configuration
The output of the ST30 board is connected directly to the input of the CompactiMa
module (if using CX500 or MultiMa) or the XP input module (if using MultiMa).
In the software, you need to specify that the sensor (the ST30 board) has an output of
0 - 20 mA.
5.1
CX500
Do you have a CX500? Use CX Assistant to set the output of the setting correctly.
Select your External start contact.
To find this, navigate this path:
System - Irrigation unit -
Irrigation group.
Click the IO Settings button.
The
Change IO Settings
window
opens.
Select 'Universal sensor [0 - 100 [%]]'
with an output of 0 - 20 [mA].
Click the OK button.
The
Change IO Settings
window
closes.
You have set that the sensor has an output
of 0 - 20 mA.