If the measured value is lower than or equal to the pre-set end value, then the
maximum influence will be applied.
Max. influence on irrigation cycle: -500 - 500 %
The maximum influence on the size of the irrigation cycle, resulting from the contact
input value (e.g. from a weighing scale).
See also: "Cont.value for start influence 0 - 100 %" on the previous page.
A contact value influence is only applied to irrigation. It is not applied to crop pre-
rinsing and post-rinsing, or to frost prevention sprinkling.
Central contact
No: The central contact will not be used for a contact start.
Yes: The central contact will be used for a contact start.
Ignore main pause time
No: The valve group will only be activated once the main pause time has elapsed.
Yes: The valve group will be activated immediately, even if the main pause time has
not yet elapsed.
If the valve group is already active, the start signal will not be stored.
If another valve group is already active, the start signal will be queued.
3.3.1.10
Radiation start
Radiation start active
Start time
End time
Minimum radiation level
Radiation sum for start
Reset radiation counter
Path: Settings>Programs>Program name>Radiation start
Radiation start active
No: Not active.
Yes: Active.
Start time of radiation start
The time after which a radiation start may take place:
Real time: fixed point in time.
Sunrise: time before (-) or after sunrise.
Sunset: time before (-) or after sunset.