S9922 3G/4G Router User Manual
RICON: Mobile Connect Tecnology
Table 5-15
IP filter parameter instruction
Parameter
Details
Operation
Type
To select an IP filter type, “Basic” or
“Expand”.
Basic: standard IP filter, not for
port.
Expand: for specific port IP filter.
Select “Basic” or “Expand”.
ID
To name this rule.
Value range: [2000,2699]
for “Basic”;
Value range: [3000,3699]
for “Expand”.
Default action
The default action of this rule, to
choose “Accept” or “Drop”
Accep: firewall will accept this
package and allow this package
pass.
Drop: firewall will drop this
package.
Select “Accept” or “Drop”.
Protocol
To set data communication protocol,
for “Basic” type, “TCP”, “UDP”, ICMP”
or “ALL” can be selected. For
“Expand” type, “TCP” or “UDP” can
be selected.
To select one in
DropDownList
Source type
(only for
“Basic”)
IP address type of data source end,
“custom”, “any” or “host” can be
selected
Custom: IP address will be
customized.
Any: any IP address.
Host: for single IP address.
Select from DropDownList
Source IP
To set IP address of data source end
(when “Source type” is selected as
“custom” and “host”).
Format: A.B.C.D type.
Wildcard Bits
To set the wildcard bits of data
sending end.
(only for “custom” in “source type” in
“Basic”.)
Format: A.B.C.D type.
Содержание S9922
Страница 1: ...User Manual S9922 LTE Router...
Страница 2: ......
Страница 19: ...S9922 3G 4G Router User Manual RICON Mobile Connect Tecnology...
Страница 116: ...S9922 3G 4G Router User Manual RICON Mobile Connect Tecnology Figure 6 3 parameter select setting 1...
Страница 121: ...S9922 3G 4G Router User Manual RICON Mobile Connect Tecnology Figure 6 11 router off line Figure 6 12 router reboot...
Страница 130: ......