background image

32DFR114.A 

4 - 7 

5. 

ADJUSTING THE DEPLOY AND STOW PRESSURE SETTINGS 

Refer to 

Figure 4-1.

  Separate pressure adjustments are available for the deploy and stow motions.  The two 

valves used to make these adjustments are on the pump body. 

a. 

Apply power to ramp, then deploy ramp and remove component access cover. 

b. 

Verify that oil reservoir is filled. 

         CAUTION 

Wear safety glasses.  Residual pressure may be in the hydraulic system, which can spray 
fluid when first loosening the fittings.  Be prepared with rags to catch fluid that spills. 

c. 

Refer to 

Figure 4-2.

  Disconnect the two rotary actuator hydraulic lines that connect to the ports on 

the backside of the pump body.  Cap off the upper deploy port fitting and connect a suitable 
pressure gauge to the lower stow port fitting. 

d. 

Press and hold the STOW button on the pendant and adjust the stow pressure setting valve to 
1,500 psi for a 59” ramp or 1,100 psi for a 48” ramp.  Loosen the lock nut on the valve and engage 
the adjustment screw with a ¼” hex key wrench to adjust.  Tighten lock nut after adjustment. 

e. 

Refer to 

Figure 4-3 

on the following page

.

  To check the deploy pressure, cap off the lower stow 

port fitting and connect the gauge to the upper deploy port. 

DEPLOY PRESSURE

SETTING VALVE

STOW PRESSURE
SETTING VALVE

DEPLOY PRESSURE
PORT (TO ACTUATOR)

STOW PRESSURE

PORT (TO ACTUATOR)

FIGURE 4-1:  HYDRAULIC PUMP ASSEMBLY 

FIGURE 4-2:  PRESSURE GAUGE CONNECTED TO STOW PORT 

Содержание BR2SS Series

Страница 1: ...it breaker tripped Reset circuit breaker Hydraulic pump circuit breaker tripped Reset circuit breaker Vehicle interlock conditions not met Check that all interlock conditions are met before attempting...

Страница 2: ...y turning them fully clockwise Readjust valves as shown in section C 5 in this chapter Hydraulic fluid level low Check hydraulic fluid level refill as required Low hydraulic pressure Check that hydrau...

Страница 3: ...ve Check for PUMP SOLENOID INPUT signal at controller connector pin J4 4 Replace controller if necessary Hydraulic pump does not operate pump solenoid does not operate Pump wiring harness defective Ch...

Страница 4: ...Repair as required Replace hydraulic pump Hydraulic pump wiring harness defective Repair or replace harness from electronic controller to hydraulic pump Pump directional valve defective Replace hydrau...

Страница 5: ...adjustment Verify that proximity sensor is energized LED on sensor indicates operation and adjusted for correct gap Refer to section B 6 in this chapter Ramp will function in one direction but not th...

Страница 6: ...terface connector See Table 4 2 for pin layout and signal descriptions Table 4 2 CONNECTOR PIN LAYOUT AND DESCRIPTION Pin Wire color Description Volts amps 1 White Interlock common Ground for interloc...

Страница 7: ...connect to the ports on the backside of the pump body Cap off the upper deploy port fitting and connect a suitable pressure gauge to the lower stow port fitting d Press and hold the STOW button on the...

Страница 8: ...s NOTE If ramp does not stow fully repeat steps c and d above Readjust stow pressure by turning the stow pressure setting valve 1 8 turn CW until ramp stows k Press the DEPLOY button on the pendant to...

Страница 9: ...target segment must be directly in front of a sensor Adjust as necessary c Refer to Figure 4 6 Loosen jam nuts on sensor body Adjust position of both nuts to achieve a gap between nose of sensor and...

Страница 10: ...a Visually inspect ramp for loose or missing hardware and fittings and confirm that pockets are free of debris b Verify that bottom cover is installed on ramp c Verify that non skid flooring is clean...

Отзывы: