7. Image Quality Problem: Full Page
Uneven Density
Uneven Density: 189 mm (7.5 inches) Pitch
Density fluctuation occurs at intervals of 189 mm (7.5 inches).
189 mm (7.5 in.)
189 mm (7.5 in.)
CNT002
Cause:
If the machine is left unattended for a long period in an environment where temperature and humidity
are high, corona products on the photoconductor unit absorb moisture to prevent a buildup or removal
of static electricity on the photoconductor unit.
Solution:
1.
In the [Machine: Maintenance] group on the [Adjustment Settings for Operators] menu,
execute 0501: [Execute Process Adjustment].
2.
Print the image. Has the problem been resolved?
Yes
Finished!
No
Execute 0501: [Execute Process Adjustment].
3.
Repeat step 2. If the problem persists even though you have repeated Step 2 five times or
more, contact your service representative.
59
Содержание TCRU/ORU
Страница 2: ......
Страница 10: ...8...
Страница 18: ...1 Before You Begin 16...
Страница 20: ...2 Troubleshooting Service Call Problems SC Codes 18...
Страница 48: ...For details about replacing the photoconductor unit see Replacement Guide 5 Image Quality Problem Lines 46...
Страница 60: ...6 Image Quality Problem Spots 58...
Страница 84: ...7 Image Quality Problem Full Page 82...
Страница 132: ...8 Troubleshooting Paper Delivery Problems 130...
Страница 160: ...9 Post Processing Option Troubleshooting 158...
Страница 183: ......
Страница 184: ...EN GB EN US EN AU D0AK 7433 2018...