appears after performing the Banding 63 mm intervals solution, restore the original Paper Transfer
Roller value.
Banding: 189 mm (7.5 inches) Intervals
Density fluctuation occurs at intervals of 189 mm (7.5 inches).
189 mm
(7.5 in.)
DFP395
Cause:
This may occur if:
• When the environment changes from high temperature or humidity to low temperature or humidity
• Halftone images are printed
Solutions:
1.
In the [Machine: Maintenance] group on the [Adjustment Settings for Operators] menu,
execute 0501: [Execute Process Adjustment].
2.
Print the image. Has the problem been resolved?
Yes
Finished!
No
Repeat Steps 1 to 2. If the problem persists even if you repeat this solution 3 times,
perform the solution specified in page 47 "Banding: General".
Banding: Horizontal White Bands (S mode)
Horizontal white streaks at intervals of 6 mm.
Bands
51