1.Detailed Descriptions
45
•
Replace the cartridge after the staples have completely run out (End).
•
Replace the cartridge with the machine’s power on (so that the device status can be monitored).
What if the counter does not match the actual remaining number of staples?
•
After replacing the cartridge, set SP6-795-002 / SP6-796-002 (Staple N.E. Setting: Staple
Remaining Setting) to the maximum value.
•
If some degree of mismatch is tolerable, change the value according to the estimated number of
remaining staples in the new cartridge.
Automatic Counter Reset
After reaching the near-end status, if the staples do not run out (End) even after the number of staples
used exceeds 1.5 times that of the specified number of staples in the near-end status, the counter is
automatically reset according to the determination that the staples have been replaced. The automatic
counter reset function can be set on/off on the corresponding SP.
SP6-796-003/007 (Staple N.E. Setting: Anomaly Near-End Disp. Clear Setting)
0: Reset
1: Do not reset
Содержание SR3260
Страница 2: ......
Страница 6: ......
Страница 16: ...1 Detailed Descriptions 10 658 x 665 x 960 mm 25 9 x 24 5 x 37 8 inches Weight Approx 34 kg 75 0 lb...
Страница 45: ...1 Detailed Descriptions 39 Stapler movement process The movement differs between Single and Double stapling...
Страница 58: ...1 Detailed Descriptions 52...
Страница 92: ...2 Replacement and Adjustment 86 4 Remove the Feedout Pawl Motor STM4 A from the bracket...
Страница 103: ...2 Replacement and Adjustment 97 2 Remove the Paper guide HP sensor S37 A...
Страница 106: ...2 Replacement and Adjustment 100 8 Remove the guide plate A 9 Remove the stapler cartridge A 10 Remove the cover A 2...
Страница 122: ...2 Replacement and Adjustment 116 3 Remove the Booklet Transport Lower Pressure Release HP Sensor S5 A...
Страница 128: ...2 Replacement and Adjustment 122 Secure the harness so that the relay connector A is above the clamp B...