![Ricoh Pro C5100S Скачать руководство пользователя страница 107](http://html1.mh-extra.com/html/ricoh/pro-c5100s/pro-c5100s_operating-instructions-manual_1455206107.webp)
71: [Txt Ppr: AC Duty Cycl of Ppr Trns Vltg]
Adjust the duty cycle of the AC voltage applied to the paper when Textured Paper mode is enabled.
Press [+] to increase the duty cycle and [−] to reduce it.
Setting Items
Max. Value
Min. Value
Step
Unit
[Txt Ppr: AC Duty Cycle of Paper Transfer
Voltage]
50
5
1
%
72: [Txt Ppr: Ppr Trns Isolatn Voltag: Side 1]
Adjust the separation voltage for paper transfer applied to Side 1 when Textured Paper mode is
enabled.
Press [+] to increase the voltage and [−] to reduce it.
Setting Items
Max. Value
Min. Value
Step
Unit
[Txt Ppr: Ppr Trns Isolation Voltage: Side 1]
12.0
0.0
0.5
KV
* You can adjust the value in steps of 0.1 kV using from Web Image Monitor.
73: [Txt Ppr: Ppr Trns Isolatn Voltag: Side 2]
Adjust the separation voltage for paper transfer applied to Side 2 when Textured Paper mode is
enabled.
Press [+] to increase the voltage and [−] to reduce it.
Setting Items
Max. Value
Min. Value
Step
Unit
[Txt Ppr: Ppr Trns Isolation Voltage: Side 2]
12.0
0.0
0.5
KV
* You can adjust the value in steps of 0.1 kV using from Web Image Monitor.
Fuser Adjustment
74: [Fusing Heat Roller Temperature Adj]
Adjust the heat roller temperature.
Press [+] to increase the temperature and [−] to reduce it.
Setting Values
105
Содержание Pro C5100S
Страница 2: ......
Страница 8: ...6...
Страница 16: ...Display only You can check the setting for the selected item 1 Adjustment Settings for Skilled Operators 14...
Страница 64: ...2 Details of Menu Items in Adjustment Settings for Skilled Operators 62...
Страница 72: ...3 Custom Paper Settings for Administrators 70...
Страница 122: ...MEMO 120 EN GB EN US EN AU D138 7435...
Страница 123: ......
Страница 124: ...EN GB EN US EN AU D138 7435 2013...