T
echnical
B
ulletin
PAGE: 2/2
Model: Vacuum Feed LCIT RT5100
Date: 12-Sep-19
No.: RD777018
2. Paste the Mylar to the feeler.
IMPORTANT:
Paste it so that it does not extend beyond the edge
[a]
of the feeler. The detection timing
may be change, which may cause other trouble.
Does not use transparent Mylar.
Adjust the length
[b]
according to the gap
[c]
of the actual machine.
GAP
[c] mm
Length
[b] mm
1
0.5
2
1
2.5
2
3
2.5
3.5
3
4
3.5
3. Attach the feeler in the reverse order and check the following to confirm the effectiveness:
-
Whether the SC recurs by lifting the tray
-
Whether Mylar is interfering with other parts during lifting
-
Whether there is any indication that the Mylar has hit/contacted something
-
Whether the bottom plate is inclined