Q: What is the Pixel shft Resolution ?
A: The in-body SR (shake reduction) mechanism is used to move the image sensor unit in minute
increments, a single pixel pitch at a time, to capture four shots. Pixel Shift Resolution merges those
shots into a single image to generate an ultra high-definition image. This method differs from the
traditional Bayer method, which acquires only a single element of color information for single pixel, by
acquiring all RGB color information for individual pixel. This difference makes it excellent for detail and
color reproduction, creating super high-definition images. This also prevents false colors from occurring
theoretically, and also has a high-sensitivity noise reduction effect when compared to normal shooting.
Photographed RAW images can be processed on the camera and also developed using the included
utility software as Pixel Shift Resolution.
*Be sure to use a tripod for thorough stabilization when shooting.
*When shooting, use Drive Mode options: Self-timer, Remote Control, or Mirror Lock-up Shooting.
*Effects may not be gained if the subject moves or the camera shakes.
Q: What are the setting modes and functions of Pixel Shift Resolution II System?
A: There are following four capture settings available.
Tripod (Motion
Corr.On)
Reduces mosaic-pattern noise when a moving object is detected.
Tripod (Motion
Corr.Off)
Does not detect moving objects.
Off
Does not use Pixel Shift Resolution.
When shooting is performed, captured four images and then they are merged into a single image.
Memo
:
Caution:
*This function cannot be used in the following situations.
・
In B or X mode.
・
In Movie mode.