![Ricoh M095 Скачать руководство пользователя страница 171](http://html.mh-extra.com/html/ricoh/m095/m095_service-manual_1455009171.webp)
Service Menu
SM 5-31
M095/M096/M099/M100
Syste
m
Ma
in
te
na
n
ce
Ref
eren
ce
TX Settings
Redial Interval
Sets the redial interval when Tx fails.
[5 Min/ 6 Min]
Redialings
Sets the number of redials when Tx fails.
[2 times/ 3 Times/ 4 Times/ 5 Times]
Overseas Comm
Mode Settings
Overseas
Comm Mode
This sets the machine to ignore a DIS signal sent
from the called station once in a sending
operation.
[Off (Default)/ Ignore DIS Once]
Minimum Time
Length
If this setting is set to "On", the machine detects
the CNG signal after the line is connected. If it is
set to "Off", the machine detects the CNG signal
as long as the line is connected.
[100 Ms/ 200 Ms/ 300 Ms/ 400 Ms (Default)]
Dial Pulse Setting Dial Pulse Type
This sets the number of pulses that are generated
during dialing.
N: Dialing '0' generates 10 pulses --- Dialing
'9' generates 9 pulses.
N+1: Dialing '0' generates 1 pulses --- Dialing
'9' generates 10 pulses.
10-N: Dialing '0' generates 10 pulses ---
Dialing '9' generates 1 pulse.
Tone Signal
Settings
Tone Signal
Transmission
Time Length
Sets the tone signal transmission time length
[100 ms (Default)]
Minimum Pause
in Tone Dialing
Sets the minimum pause during tone dialing
[100 ms (Default)/ 150 ms/ 200 ms]
Attenuator For
Pseudo
RingBack tone
To the Line
Sets the attenuator for pseudo ringback tone to
the line
[0 to 15 / 10 (Default)/ 1 dB/step]
DTMF Level
Sets the transmission level of DTMF tones.
[-12 dBu / -11 dBu/ -10 dBu/ -8 dBu/ -6 dBu]
Содержание M095
Страница 1: ...M095 M096 M099 M100 SERVICE MANUAL ...
Страница 2: ......
Страница 6: ......
Страница 16: ......
Страница 17: ...PRODUCT INFORMATION REVISION HISTORY Page Date Added Updated New None ...
Страница 18: ......
Страница 29: ...INSTALLATION REVISION HISTORY Page Date Added Updated New None ...
Страница 30: ......
Страница 34: ......
Страница 35: ...PREVENTIVE MAINTENANCE REVISION HISTORY Page Date Added Updated New None ...
Страница 36: ......
Страница 38: ......
Страница 39: ...REPLACEMENT AND ADJUSTMENT REVISION HISTORY Page Date Added Updated New None ...
Страница 40: ......
Страница 66: ...Image Transfer M095 M096 M099 M100 4 26 SM 4 6 3 AGITATOR MOTOR 1 Right cover p 4 7 2 Motor bracket A x 2 ...
Страница 92: ...Paper Exit M095 M096 M099 M100 4 52 SM 4 Remove the four exit guides C and gear D bushing x 1 ...
Страница 106: ...Electrical Components M095 M096 M099 M100 4 66 SM 6 Fusing stripper pawl solenoid B x 2 ...
Страница 112: ...Electrical Components M095 M096 M099 M100 4 72 SM 7 PSU assembly E x 4 x 7 8 PSU F x 4 ...
Страница 134: ...Scanner only for MF Models M095 M096 M099 M100 4 94 SM 6 Bar holder D x 1 7 Carriage bar E and scanner carriage unit F ...
Страница 138: ......
Страница 139: ...SYSTEM MAINTENANCE REFERENCE REVISION HISTORY Page Date Added Updated New None ...
Страница 140: ......
Страница 184: ......
Страница 185: ...ENVIRONMENTAL CONSERVATION REVISION HISTORY Page Date Added Updated New None ...
Страница 186: ......
Страница 192: ......
Страница 193: ...M095 M096 M099 M100 SERVICE MANUAL APPENDICES ...
Страница 194: ......
Страница 196: ......
Страница 197: ...APPENDIX SPECIFICATIONS REVISION HISTORY Page Date Added Updated New None ...
Страница 198: ......
Страница 224: ......
Страница 225: ...PAPER FEED UNIT TK1010 G849 PAPER FEED UNIT TK1010 G849 REVISION HISTORY Page Date Added Updated New None ...
Страница 226: ......
Страница 228: ......
Страница 230: ......
Страница 236: ......