3-2-3. Format of the Service Report and Error Report Generation Area
The Service Report and the Error Report are generated in addresses 2272 - 2433 (H). The record of each error
communication is stored in blocks of 45 bytes as explained in the following table. There can be up to 10 records.
Byte No.
Functions
0
Header
Bit 7: Service Report or Error Report
(1: Enabled)
Bit 6 through 0: Not used
1 - 29
Same as the TCR memory
30
Error page #1
(BCD)
31
Error page #2
(BCD)
32
Error page #3
(BCD)
33
Error page #4
(BCD)
34
Error page #5
(BCD)
35
Error code #1 (High)
(BCD)
36
Error code #1 (Low)
(BCD)
37
Error code #2 (High)
(BCD)
38
Error code #2 (Low)
(BCD)
39
Error code #3 (High)
(BCD)
40
Error code #3 (Low)
(BCD)
41
Error code #4 (High)
(BCD)
42
Error code #4 (Low)
(BCD)
43
Error code #5 (High)
(BCD)
44
Error code #5 (Low)
(BCD)
3-2-4. Format of the Error Code Memory
The error codes are stored in 2438 - 24F7 (H). Each error code is stored in blocks of 6 bytes as explained in the fol-
lowing table. The machine can store up to 32 error codes.
Byte No.
Functions
0
Error code (High)
(BCD)
1
Error code (Low)
(BCD)
2
Month
(BCD)
3
Day
(BCD)
4
Hour
(BCD)
5
Minute
(BCD)
3-10