Slide 166
LPH Replacement and Adjustment
LED Head 2
LED Heads 1 and 3
LPH REPLACEMENT AND ADJUSTMENT
What are these settings?, continued
The diagram shows the LPH unit, above the drum.
There are three heads, LPH 1, LPH 2, and LPH 3. LPH 2 is in the centre.
Clearly, they are not in the same position above the drum in the sub scan
direction.
¾
Two of the heads (LPH 1 and LPH 3) are almost (but probably not exactly)
in the same place, but the gap between these and the central one (LPH 2)
is considerably larger.
SP 2952 011 and 012 tell the machine the misalignment between the three
heads in the sub-scan direction. The machine will adjust the writing timing for
each of the heads, using these settings, to make sure that each scan line of the
latent image is written across the drum correctly.
¾
We will see this more clearly later during the adjustment procedure in the
manual.
Содержание Beluga-C1
Страница 100: ...Beluga C1 C1 5 Training 100 Slide 100 VM Card The VM card must stay in slot 2 No additional notes ...
Страница 110: ...Beluga C1 C1 5 Training 110 Slide 110 INSTALLATION Updating Firmware No additional notes ...
Страница 113: ...Beluga C1 C1 5 Training 113 Slide 113 INSTALLATION Transporting the Machine No additional notes ...
Страница 155: ...Beluga C1 C1 5 Training 155 Slide 155 Quenching Lamp LED array The lamp contains red LEDs to prevent drum fatigue ...
Страница 226: ...Beluga C1 C1 5 Training 226 Slide 226 Fusing Unit Drive Fusing exit motor Drives the fusing unit No additional notes ...
Страница 236: ...Beluga C1 C1 5 Training 236 Slide 236 Exit Guide Open here to remove jams No additional notes ...
Страница 253: ...Beluga C1 C1 5 Training 253 Slide 253 End of Course No additional notes ...