NCU PARAMETERS
B547 102
SM
Address Function
Unit
Remarks
6805BE
to
6805C6
Not used
Do not change the
settings.
6805C7
Bits 0 to 3 – Not used.
Bit 4 – V.34 protocol dump
0:
Simple,
1:
Detailed (default)
Bits 5 to 7 – Not used.
6805C8
to
6805D9
Not used
Do not change the
settings.
6805DA
T.30 T1 timer
1 s
6805E0
bit 3
Maximum wait time for post
message
0:
12 s
1:
30 s
1:
Maximum wait time for
post message
(EOP/EOM/MPS) can be
changed to 30 s.
Change this bit to “1” if
communication errors
occur frequently during
V.17 reception.
NOTES:
1. If a setting is not required, store FF in the address.
2. Italy and Belgium only
RAM address 68055E: the lower four bits have the following meaning.
Bit 2 - 1: International dial tone cadence detection enabled (Belgium)
Bit 1 - Not used
Bit 0 - 1: PSTN dial tone cadence detection enabled (Italy)
If bit 0 or bit 2 is set to 1, the functions of the following RAM addresses are
changed.
680508 (if bit 0 = 1) or 680538 (if bit 2 = 1): tolerance for on or off state
duration (%), and number of cycles required for detection, coded as in address
680533.
68050B (if bit 0 = 1) or 68053B (if bit 2 = 1): on time, hex code (unit = 20 ms)
68050C (if bit 0 = 1) or 68053C (if bit 2 = 1): off time, hex code (unit = 20 ms)
3. Pulse dial parameters (addresses 68054A to 68054F) are the values for 10
pps. If 20 pps is used, the machine automatically compensates.
4. The first ring may not be detected until 1 to 2.5 wavelengths after the time
specified by this parameter.
5. The calculated level must be between 0 and 10.
The attenuation levels calculated from RAM data are:
High frequency tone: – 0.5 x N
680552/680554
–3.5 dBm
– 0.5 x N
680555
dBm
Low frequency tone: – 0.5 x (N
680552/680554
+ N
680553
) –3.5 dBm
– 0.5 x (N
680555
+ N
680553
) dBm
NOTE:
N
680552
, for example, means the value stored in address 680552(H)
Содержание B079
Страница 1: ...B079 B082 SERVICE MANUAL 001634MIU RICOH GROUP COMPANIES ...
Страница 2: ......
Страница 3: ...B079 B082 SERVICE MANUAL RICOH GROUP COMPANIES ...
Страница 4: ......
Страница 5: ...B079 B082 SERVICE MANUAL 001634MIU ...
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 12: ......
Страница 26: ......
Страница 28: ......
Страница 29: ...INSTALLATION ...
Страница 30: ......
Страница 101: ...PREVENTIVE MAINTENANCE ...
Страница 102: ......
Страница 107: ...REPLACEMENT AND ADJUSTMENT ...
Страница 108: ......
Страница 196: ......
Страница 197: ...TROUBLESHOOTING ...
Страница 198: ......
Страница 221: ...Trouble shooting SERVICE CALL CONDITIONS SM 4 23 B079 B082 INTENTIONALLY LEFT BLANK ...
Страница 225: ...SERVICE TABLES ...
Страница 226: ......
Страница 330: ......
Страница 331: ...DETAILED SECTION DESCRIPTIONS ...
Страница 332: ......
Страница 436: ......
Страница 437: ...SPECIFICATIONS ...
Страница 438: ......
Страница 448: ......
Страница 449: ...BOOKLET FINISHER B546 ...
Страница 450: ......
Страница 497: ...AUTO REVERSE DOCUMENT FEEDER B541 ...
Страница 498: ......
Страница 525: ...LARGE CAPACITY TRAY B543 ...
Страница 526: ......
Страница 528: ......
Страница 543: ...PAPER TRAY UNIT B542 ...
Страница 544: ......
Страница 546: ......
Страница 565: ...1 BIN TRAY B544 ...
Страница 566: ......
Страница 568: ......
Страница 576: ......
Страница 577: ...1000 SHEET FINISHER B408 ...
Страница 578: ......
Страница 580: ......
Страница 605: ...TWO TRAY FINISHER B545 ...
Страница 606: ......
Страница 643: ...BRIDGE UNIT B538 ...
Страница 651: ...PRINTER OPTION B548 ...
Страница 652: ......
Страница 703: ...FAX OPTION B547 ...
Страница 704: ......
Страница 708: ......
Страница 851: ...TECHNICAL SERVICE BULLETINS ...
Страница 853: ...BRIDGE UNIT B538 ...
Страница 908: ...Trouble shooting SERVICE CALL CONDITIONS SM 4 23 B079 B082 INTENTIONALLY LEFT BLANK ...
Страница 941: ...FIRMWARE HISTORY ...