background image

2

 

 

Scope of delivery 

 

RiCo Ethernet Converter 

 

Power supply unit (7.5 VDC / 600 mA) 

 

RJ45 Patch cable (2 m) 

 

Crossover adapter 

 

Manual 
 

Function 

The Ethernet Converter establishes a connection between a Solar-Log data logger and 

a RiCo large display. The Ethernet Converter communicates with the Solar-Log via the 
network interface (10/100 Mbit), using TCP. The Ethernet Converter and the Solar-Log 
must be in the same local area network and the same subnet. The Ethernet Converter 
receives the actual data from the Solar-Log (actual power, daily energy, total energy). 
Instead of using a local area network both devices can be connected together directly 
via a crossover link. 

 
The  data  is  transmitted  to  the  large  display  via  the  RS-485  interface.  This  allows  a 
cabling length up to 1000 meters between the Ethernet Converter and the display. A 
shielded data cable is used for the connection, for example JY-ST-Y, CAT5. A twisted 
wire pair must be used for data connection. 

Important hints 

 

The Solar-Log must have firmware version 3.1.3 or above 

 

The installation of the plant and all connected devices must be finished 

 

The IP address of the Solar-Log and the Ethernet Converter are static and both 
must be unique in the local area network 

 

The RiCo large display must be configured to data source number ’7’ 

 

The Ethernet Converter is supplied with the delivered power supply (7.5 VDC) 

 

The Ethernet Converter and the power supply unit are for indoor use only 