background image

Declaration about the Contamination of 
Richter Pumps, -Valves 
and Components 

Prepared:

 

CRQ/Lam 

on

:

 

Nov. 13, 2006

 

Page:

  2 

QM-Nr.:

 0912-16-2001_de/4-

07

 

Approved:

 

CRQ/Zu 

on

:

  Nov. 13, 2006

 

of  :

 

The repair and/or maintenance of pumps, valves and components can only be implemented if a completely filled out declaration is 
available. If this is not the case, delay of the work will occur. If this declaration is not attached to the devices, which have to be 
repaired, the transmission can be rejected. 

Every aggregate has to have i

t’s own declaration.

 

This declaration may be filled out and signed only by authorized technical personnel of the operator. 

 

Contractor/dep./institute : 

 

Reason for transmitting 

 Please mark the applicable 

 

 

Repair:

 

 subject to fee 

 Warranty 

Street : 

 

Austausch:

 

 subject to fee 

 Warranty 

Postcode, city : 

 

 Exchange/ Replacement already initiated/received 

Contact person : 

 

Return

 Leasing 

 Loan 

 for credit note 

Phone : 

Fax : 

 

 

End user 

 

 

A.  Details of Richter-product: 

 

 

Failure description: 

Classification: 

 

   

Article number: 

 

 

 

Serial number: 

 

 

 

 

 

 

 

 

   

B.  Condition of the Richter-

product: 

 

no

1)

  yes 

no 

   

Contamination : 

 

no

1)

 

yes 

 

Was it in operation ? 

 

 

 

 

 

toxic 

 

 

 

 

Drained (product/operating supply item) ? 

 

 

 

 

   

caustic 

 

 

 

 

All openings hermetically locked! 

 

 

 

   

inflammable 

 

 

 

 

Cleaned ? 

 

 

 

 

   

explosive

2)

 

 

 

 

 

If yes, with which cleaning agent: 

 

 

 

   

mikrobiological

2)

 

 

 

 

 

and with which cleaning method: 

 

 

 

   

radioactive

3

)

 

 

 

 

1)

 if "no", then forward to 

D

.

 

 

   

other pollutant 

 

 

 

 

2)

 Aggregates, which are contaminated with microbiological or explosive substances, are only accepted with 

documented evidence of an approved cleaning. 

3)

 

Aggregates, which are contaminated with radioactive substances, are not accepted in principle. 

 

C.  Details of the discharged materials (must be filled out imperatively) 

 

 

1.

 

With which materials did the aggregate come into contact ?

 Trade name and/or chemical designation of 

operational  funds  and  discharged  materials,  material  properties,  e.g.  as  per  safety  data  sheet  (e.g.  toxic, 
inflammable, caustic) 

  X    Trade name: 

Chemical designation: 

 

  a) 

 

 

  b) 

 

 

  c) 

 

 

  d) 

 

 

 

 

no 

yes 

 

 

2.  Are the materials specified above harmful to health ? 

 

 

 

 

3.  Dangerous decomposition products during thermal load ? 

 

 

 

 

 

If yes, which ones? 

 

 

 

 

 

 

D.  Mandatory declaration:

  

We assure that the data in this explanation are truthful and complete and as a signatory I am able 

to form an opinion about this. We are aware that we are responsible  towards the contractor for damages, which results from 
incomplete and incorrect data. We commit ourselves to exempt the contractor from claims for damages of thirds resulting from 
incomplete  or  incorrect  data.  We  are  aware  that  we  are  directly  responsible  towards  thirds,  irrespective  of  this  declaration, 
which belongs in particularly to the employees of the contractor consigned with the handling repair of the product.

 

 

 

   

 

 

   

 
 
 
 

 

Company stamp 

Name of the authorized person 
(in block letters):

 

 

 

 

 

 

Date 

 

Signature 

 

 

Содержание KNAR-D/F Series

Страница 1: ...n and maintenance Subject to change without notice Reproduction is generally permitted with indication of the source Richter Chemie Technik GmbH 9520 032 en Revision 15 Edition 11 2018 Series KNAR F K...

Страница 2: ...valve with actuator 12 9 2 Assembly 12 9 2 1 Packing bellows 12 9 2 2 Ball valve with lever 12 9 2 3 Ball valve with actuator 12 9 3 Conversion from lever to actuator 13 10 Drawings 13 10 1 Legend 13...

Страница 3: ...5 KNAR S F KNARP S F Stainless steel 1 4408 CF8M 316 Lining material PFA PTFE F On request antistatic F L highly permeation resistant F P Temperature range See pressure temperature diagram in Section...

Страница 4: ...The end of the stem journal or flat pivot point is marked with flow direction flow rate Kvs and Cv lining material As viewed from above closing is in clockwise direction 1 3 Tightening torques All scr...

Страница 5: ...id damage to the valve it is imperative to observe the max admissible actuating torque 1 5 Cavitation coefficient z for 75 duty Cv Cv100 0 75 There are at least 3 different V control ball stem units f...

Страница 6: ...used in the area of application of ASME the low temperature of ASTM A395 is limited to 20 F 29 C A special material is used for the ball stem unit for operating limits under 14 F to 76 F 10 C to 60 C...

Страница 7: ...urs gases and non boiling liquids of group 1 according to the PED and have a corrosion resistant plastic lining Solids can lead to increased wear damage to sealing surfaces or to a reduction in the se...

Страница 8: ...ot completely filled with medium e g during evacuation and filling the formation of an explosive atmosphere must be prevented e g by superimposing a layer of nitrogen It is recom mended to wait 1 hour...

Страница 9: ...ipt of the goods the consignment must be checked for completeness and any in transit damage Do not damage paint protection 5 1 Storage If the valve is not installed immediately after delivery it must...

Страница 10: ...ock washers One pipe screw per flange is underlaid with toothed disks At the customer s request a setscrew M6 with a hex nut and washer will be provided at each flange as an additional grounding conne...

Страница 11: ...mechanical damage by using flange caps See also Section 6 1 Make sure that a remote controlled actuator cannot be switched on by accident 8 Malfunctions Flange connection ball valve pipe is leaking R...

Страница 12: ...escribed in Section 9 1 1 9 2 Assembly Prior to assembly all parts are to be cleaned and the plastic lined parts checked for damage Insert seat rings 401 in the main body 101 and body end piece 102 As...

Страница 13: ...of V control ball stem unit Observe the actuator position in accordance with the actuator operating manual Tighten setscrew 904 4 in the coupling 804 Tighten sleeve nut 512 on the coupling tight Atte...

Страница 14: ...KNARP F KNAR D F KNARP D F Page 14 KNAR S F KNARP S F ASME 9520 032 en Revision 15 TM 9549 Edition 11 2018 10 2 Sectional drawing ball valve with lever Holes of the flange and housing screws view dis...

Страница 15: ...KNARP F KNAR D F KNARP D F Page 15 KNAR S F KNARP S F ASME 9520 032 en Revision 15 TM 9549 Edition 11 2018 10 3 Sectional drawing ball valve with actuator Holes of the flange and housing screws view d...

Страница 16: ...View and section ball valve with lever View Z Section B B 10 5 Sections ball valve with actuator Section A A Section B B Section B B Tighten packing gland follower 503 until spring gland follower 502...

Страница 17: ...lever KNAR F x x x x x x x x KNAR S F x x x DN 1 1 2 3 4 6 8 L inch mm 5 12 130 5 91 150 5 0 127 6 5 165 7 0 178 7 99 203 9 01 229 10 51 267 17 99 457 HL inch mm 7 05 179 10 24 260 12 32 313 20 27 515...

Страница 18: ...15 80 4 64 118 5 27 134 7 24 184 H2 inch mm 2 32 60 2 32 60 3 15 80 3 94 100 H3 inch mm H4 inch mm L inch mm 5 12 130 5 91 150 5 0 127 6 5 165 7 0 178 7 99 203 9 01 229 10 51 267 17 99 457 L1 inch mm...

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ......

Страница 23: ...The laws are such as the Health and Safety at Work Act ArbSt ttV the Ordinance on Harzadous Substances GefStoffV BIOSTOFFV the procedures for the prevention of accidents as well as regulations to env...

Страница 24: ...tamination of the pumps valves and component sent in for repair On the basis of this information for the contractor is it possible to meet the necessary preventive action during the execution of the r...

Страница 25: ...ch cleaning method radioactive3 1 if no then forward to D other pollutant 2 Aggregates which are contaminated with microbiological or explosive substances are only accepted with documented evidence of...

Страница 26: ...5241 2870 Email RichterShanghai Info idexcorp com Internet www richter ct com Richter Pumps Valves Inc 406 State Street Cedar Falls 50613 IA USA Tel 1 319 268 8038 Fax 1 319 273 8157 Email RichterCed...

Отзывы: