Thank you for your purchase of a Richter Optica microscope. The information in this manual is 

provided to answer most questions that can arise when operating your microscope and to help you 

avoid unnecessary maintenance expenses in the future.

Please carefully read instructions before operating microscope. Nomenclature used to describe 

components and controls are identified on opposite page.

UNPACKING

Do not discard styrofoam container or packing materials until you are sure shipment is complete 

and undamaged (retain styrofoam shipping container to store your microscope when it is not in 

use). Remove all tape and packing material used to protect microscope during shipment. Make 

certain lens surfaces do not come in contact with dirt, fingerprints or oil. Damage of lens surfaces 

occur when they come in contact with such contaminants, and image quality is reduced.

BEFORE USE

When moving the microscope, use both hands and only lay on flat, even surfaces. Damage will 

occur by holding the stage, focusing knobs or head when moving the microscope. Hold carrying 

handle when moving the microscope.

For safety, make sure the power switch is always turned to the off position “O” before replacing 

the bulb or fuse and wait until both the bulb and bulb holder have cooled down.

Replacement bulb: Single 3w LED bulb. Part # U2-001.

SETTING UP THE INSTRUMENT

Avoid placing the instrument in locations exposed to direct sunlight, dust, vibration, high humidity 

and where it is difficult to unplug the power supply cord.

MAINTENANCE

1.  Wipe lenses only with lens paper.

2.  Never disassemble the microscope other than to change the bulb (instructions on page 6). 

Disassembling the microscope will affect performance and void warranty.

3.  Cover microscope with dust cover provided after each use.

Содержание HSX1

Страница 1: ...Richter Optica info richter optica com Instructions for Model HSX1 High School Microscope...

Страница 2: ...Carrying Handle Revolving Nosepiece Objectives Focus Tension Control Coarse Focus Fine Focus Fuse Light Rheostat Light Abbe Condenser Stage Rack Stop On Off Switch Power Cord Insertion Slide Holder X...

Страница 3: ...s occur when they come in contact with such contaminants and image quality is reduced BEFORE USE When moving the microscope use both hands and only lay on flat even surfaces Damage will occur by holdi...

Страница 4: ...ight knob while holding the other stationary Turning the coarse and fine focus knobs further than their limit 2 Using the Mechanical Stage Place a slide in the slide holder by pressing the finger leve...

Страница 5: ...ive lens Slide is upside down Cover glass is too thick High magnification objective 100x strikes the specimen when changing from low to high magnification Slide is upside down Cover glass is too thick...

Страница 6: ...2 When cleaning lenses do not use any solvents other than absolute alcohol as they may damage lens bonding cement 3 Do not use petroleum benzene when cleaning components such as lenses 4 Absolute alc...

Страница 7: ...d pulling the frame too far from the base could disconnect wires 4 The LED bulb has 2 wires soldered to it see below 5 Unscrew the bulb from its base and remove the soldered wires Take note of which c...

Отзывы: