Thank you for your purchase of a Richter Optica microscope. The information in this manual is 

provided to answer most questions that can arise when operating your microscope and to help you 

avoid unnecessary maintenance expenses in the future.

Please carefully read instructions before operating microscope. Nomenclature used to describe 

components and controls are identified on opposite page.

UNPACKING

Do not discard styrofoam container or packing materials until you are sure shipment is complete 

and undamaged (retain styrofoam shipping container to store your microscope when it is not in 

use). Remove all tape and packing material used to protect microscope during shipment. Make 

certain lens surfaces do not come in contact with dirt, fingerprints or oil. Damage of lens surfaces 

occur when they come in contact with such contaminants, and image quality is reduced.

BEFORE USE

When moving the microscope, use both hands and only lay on flat, even surfaces. Damage will 

occur by holding the stage, focusing knobs or head when moving the microscope. Hold carrying 

handle when moving the microscope.

For safety, make sure the power switch is always turned to the off position “O” before replacing 

the bulb or fuse and wait until both the bulb and bulb holder have cooled down.

Replacement bulb: 2W LED replacement module. Part #HS3-001

SETTING UP THE INSTRUMENT

Avoid placing the instrument in locations exposed to direct sunlight, dust, vibration, high humidity 

and where it is difficult to unplug the power supply cord.

MAINTENANCE

1.  Wipe lenses only with lens paper.

2.  Never disassemble the microscope other than to change the bulb (instructions on page 6). 

Disassembling the microscope will affect performance and void warranty.

3.  Cover microscope with dust cover provided after each use.

Содержание HS-3B

Страница 1: ...Richter Optica info richter optica com Instructions for Models HS 3M and HS 3B Student Compound Microscope...

Страница 2: ...ieces Binocular Head Carrying Handle Revolving Nosepiece Aperture adjustment lever Lamp Housing Lock Screw Mechanical Stage Stage X Axis and Y Axis Travel Knobs Indicator Light Condenser Coarse Focus...

Страница 3: ...cur when they come in contact with such contaminants and image quality is reduced BEFORE USE When moving the microscope use both hands and only lay on flat even surfaces Damage will occur by holding t...

Страница 4: ...wall outlet 110 240V POWER CORD STORAGE When the microscope is not in use wind the power cord as shown here in the photo POWER OPTION Cordless option Your microscope will include pre installed rechar...

Страница 5: ...n is not properly in focus Focusing is loose or too tight Adjust tension adjustment knob on the side of the microscope next to the focusing knob TROUBLESHOOTING Optical TROUBLESHOOTING Electrical PROB...

Страница 6: ...2 When cleaning lenses do not use any solvents other than absolute alcohol as they may damage lens bonding cement 3 Do not use petroleum benzene when cleaning components such as lenses 4 Absolute alc...

Страница 7: ...hese steps the microscope MUST be turned off and unplugged 1 Unplug the microscope and gently lay the microscope down on a sturdy surface ensuring the carrying handle side is down 2 Using a screw driv...

Страница 8: ...ur thumb and forefinger to pinch the sides of the plastic wire housing that holds the black and red wires 6 Using a screw driver remove the small screws on either side of the LED bulb 7 Place the new...

Страница 9: ...e it is fully inserted and secure 9 Replace the black plastic cover and secure using the 4 foot screws removed in step 2 New LED bulb Wire housing Replacement 2W LED Assembly Part HS3 001 10 Return th...

Отзывы: