background image

 

 

Richcomm System Technologies Co.,Ltd   

 

 

Tel:+86 20 6685 4299   

 

 

Fax: +86 20 8230 6916                                                                                   

             

 

            www.richcomm.com.cn/e

 

 

                       

           

 

 

19 

 

 
 

 

 

 

 

 

        Thank You For Use

 

 

 

Содержание NetmateLite

Страница 1: ...Richcomm System Technologies Co Ltd Tel 86 20 6685 4299 Fax 86 20 8230 6916 www richcomm com cn e 1 NetmateLite Basic Web based SNMP Card for UPS Installation and Setting Instruction ...

Страница 2: ... 6916 www richcomm com cn e 2 Hello Installation Requirement The monitored UPS with RS232 communication port or internal slot The computer best administrators computer with Ethernet port A complete network environment Note Please read this user manual before installation ...

Страница 3: ... port USB Port For initial configuration S1 Green Running indicator flash is normal S2 Green SNMP running indicator flash is normal flash frequency is determined by SNMP inquire cycle S3 Red Device status indicator red continuous on shows connected well with UPS and have communication flash shows device disconnected or communication failed Default Factory default switch RS232 Port External card Co...

Страница 4: ...cator often light shows device power is connected no light means not connect power S1 Green Running indicator slow flash normal S2 Green SNMP running indicator flash normal flash frequency is determined by SNMP inquire cycle S3 Red Device status indicator red continuous on shows connected well with UPS and have communication flash shows device disconnected or communication failed 4 Pin Serial Port...

Страница 5: ...Richcomm System Technologies Co Ltd Tel 86 20 6685 4299 Fax 86 20 8230 6916 www richcomm com cn e 5 2 Installation 2 1 Network Dirgram ...

Страница 6: ...llation External SNMP Cards Procedure Use DB9 pin cable connect external card with UPS by RS232 port Use T568B network cable connect to network Use power adapter connect to power supply 12V DC Internal SNMP Cards Procedure Insert internal SNMP card to solt Use T568B network cable connect to network To Network To Power ...

Страница 7: ...6 20 8230 6916 www richcomm com cn e 7 2 3 Set Network Segment For initial configuration we should set a same network segment before login in web interface the default IP address of SNMP cards are 192 168 0 100 so network segment should be set like 192 168 0 XXX ...

Страница 8: ...d Tel 86 20 6685 4299 Fax 86 20 8230 6916 www richcomm com cn e 8 2 4 Command ping Before we input input the user name and password we can check the dault IP address whether available in your network by command ping Ping Pass Ping Fail ...

Страница 9: ... e 9 2 5Login Web Monitoring Interface All above steps finished open a web browser suggest IE firefox chrome etc input default IP address 192 168 0 100 and enter Input user name and password default user name Password are both admin Users can change the User name and Password by the post setting ...

Страница 10: ...come out soon and then we can check the UPS current status and do other software setting 3 Software Setting Introdution 3 1 UPS Information Sub Menu System Information Device Information Current Status Remote Control 3 1 1 System Information This page is to display UPS basic information and network information The info shown here are provided by NetmateLite SNMP card itself and parameter settings ...

Страница 11: ...cally display when users finish the SNMP Setting E System Administrator This part will automatically display when users finish the SNMP Setting F System Installation Position This part will automatically display when users finish the SNMP Setting G Other information will be provided by NetmateLite monitoring system 3 1 2 Device Information This part is to display each part of device information UP...

Страница 12: ...running status We can clearly know about the UPS current running status when an abnormal alert happens figures will turn in red font Single phase UPS Montoring Basic Information The current figures like Input Voltage Input Frequency Battery Voltage Battery Content UPS Temperature Output Voltage Output Max Voltage Output Min Voltage Current Load are display here ...

Страница 13: ...3 2 Parameter Setting Sub Menu System Setting Network Settings SNMP Settings E mail Settings User Settings IP POWER Settings 3 2 1 System Setting Basic Parameter Settings This part is to set UPS basic parameters and the communication protocol is default Baud Rate Offline Times Alarm Times Inquiry Battery Quantity Battery Type System Date Time need to be set according to real UPS information Please...

Страница 14: ...teway information NTP server time zone and work mode of NetmateLite according to the real network segment but the IP address should not be conflicted with other device IP in a same network Also support system reboot 3 2 3 SNMP Settings This page is to set relevant settings when NetmateLite is match with SNMP software including Basic Setting Authorization Settings and TRAP Settings ...

Страница 15: ...t the snmp system administrator of the NetmateLite C SNMP System Installation Position Set NetmateLite installation location The basic setting is convenient for centralized monitoring and management when there are a lot of UPS Users can fast and sinply inquire every UPS Trap Setting Receiver IP Address is used to receive traps sent by NetmateLite Users can set 6 Trap receivers IP ...

Страница 16: ...e 16 address at most Support to choose whether receive the traps This part is to set SNMP users IP address community and relevant authorization Users can set 6 SNMP user IP address and can choose the authorization which includes No Authorization Readable and Readable Writeable 3 2 4 E mail Setting ...

Страница 17: ...2 5 User Setting This page is to set the user information which is used to login NetmateLite via Web 3 2 6 IP POWER Setting This part is to set the authorized address all the authorized address can be remote centralized managed via RichComm IP Power software Authorization item includes Control and Access ...

Страница 18: ...Richcomm System Technologies Co Ltd Tel 86 20 6685 4299 Fax 86 20 8230 6916 www richcomm com cn e 18 3 3 History Event This page is to display history events Record includes the Date Time Log Content ...

Страница 19: ...Richcomm System Technologies Co Ltd Tel 86 20 6685 4299 Fax 86 20 8230 6916 www richcomm com cn e 19 Thank You For Use ...

Отзывы: