background image

4

5

4.0 Recording Cycle Data

When the SD card is inserted into the 
SpaceLogger.D10, the Green LED on the 
front of the logger indicates that the logger 
is ready to record data.

NOTE

 – Some machines will only output 

data (to a printer or data logger) if this 
option is selected from the machine's menu 
– please read the machine's user manual or 
check with your service engineer if you are 
unsure.

NOTE

 – The SpaceLogger.D10 accepts SD 

or MMC cards up to 2GB capacity only.

record the records.

To stop logging, wait for the machine cycle 
to end then press the off button on the 
SpaceLogger keypad.

Pressing the off button ensures no 
data is lost when the SD card is 
removed.

Remove the SD card.

5.0 Importing Data Records (Log 
Files) to the SpaceLogger Cycle 
Manager Software

It is recommended that cycle records are 
transferred daily or weekly to the PC for 
backup.  The archiving of records is carried 
out automatically by the SpaceLogger Cycle 
Manager Software when Log Files are 
imported.

1.Open the SpaceLogger Cycle Manager 
Software (double click on Desktop icon).

2.Insert the SD card into the card reader 
connected to the PC.

3.Select 

File> Import Log File

 from the 

menu

4.Browse to find the SD card drive, select 
folder 

DATA

 and click on file 

LOGFILE.SLS

 

NOTE

 – To avoid losing data or corrupting 

the SD card, never remove the card or 
disconnect power when the red DATA 
RECORDING LED is on.

or 

LOGFILEX.SLS

The Log File is copied to the PC 
automatically to folder C:\SPACELOGGER 
\Imported Data Records\ (or the folder 
specified by the user during software 

install).  The Log File is also archived on 
the SD card to folder ARCHIVE.

PDF reports may be generated as required:

3

Individual Cycle Report - Click on 'Create 
Cycle PDF Report' button

3

Summary Log File Report - Click on 
'View Log File' & select 'Log File 
Summary Report'

3

Detailed Log File Report - Click on 'View 
Log File' & select 'Log File Detailed 
Report'

Green LED on = 

READY

 to record data

Red LED on = 

DATA RECORDING

 to 

SD card

Red LED on permanently & audible 
alarm = 

CARD ERROR

 – card not 

inserted or can not be written to; data is 
being lost

Run your machine for cleaning cycles as 
normal and the SpaceLogger.D10 will 

Front View of SpaceLogger.D10

Find Cycle Records by Machine Name:

·

Click on machine name to view all 
records for that device

·

Search by imported or cycle date

All the individual cycles contained in an 
imported Log File are listed in the 
summary table:

·

Sort cycles by any column 
heading

·

Right click on a cycle for more 
options

The full cycle 
printout for the 
cycle record 
highlighted in the 
summary table is 
displayed in the 
viewing pane