Installation
5
accessible from above.
4. Use the mounting plates as a templates and drill pilot holes into the floor for suitable anchor bolts.
5. Bolt the plates to the floor using 1/2'' anchor bolts.
6. Recheck foot adjustment and deck level.
Figure 2-2. Mounting Plate Installation
2.5
Electrical Interface to the Indicator
Each scale is supplied with 20' of 6-wire cable with a 6-pin connection at one end. The corresponding receptacle
connector is on the short cable coming from the junction box at the top end of the scale To connect the two cables:
1. Plug the pin end from the indicator cable into the receptacle end of the junction box cable.
2. Push the outer band on the pin connector toward the receptacle connector.
3. Turn the band one quarter to one half turn until it is finger-tight to secure the connectors together. The
cables are correctly connected if the connectors do not come apart when pulled gently.
Figure 2-3. Scale Connection to Indicator
Figure 2-4. Quick Connectors