Rice Lake RoughDeck PW-1 Скачать руководство пользователя страница 1

RoughDeck

®

 PW-1

 

Low Profile Floor Scale

Installation Manual

PN 179344

Содержание RoughDeck PW-1

Страница 1: ...RoughDeck PW 1 Low Profile Floor Scale Installation Manual PN 179344...

Страница 2: ...marks of their respective companies All information contained within this publication is to the best of our knowledge complete and accurate at the time of publication Rice Lake Weighing Systems reserv...

Страница 3: ...intenance 8 4 3 Load Cell Replacement 8 4 3 1 Remove Load Cell 8 4 3 2 Install Load Cell 8 4 3 3 Load Cell Wiring to the Junction Box 9 4 3 4 Replacement Parts List and Accessories 10 RoughDeck Limite...

Страница 4: ...ii RoughDeck PW 1 Installation Manual Rice Lake continually offers web based video training on a growing selection of product related topics at no cost Visit www ricelake com webinars...

Страница 5: ...s that are exposed when guards are removed WARNING Indicates a potentially hazardous situation that if not avoided could result in serious injury or death Includes hazards that are exposed when guards...

Страница 6: ...ted to an earth ground with a ground interface cable of no more than 3 resistance throughout its length Load Cell Excitation Rated Excitation 10 VDC Maximum Excitation 15 VDC Grade Level Requirements...

Страница 7: ...age could occur from side impacts of wheels or forklift tines Avoid areas where falling objects could cause shock damage Avoid areas where water may damage a scale not meant for a washdown environment...

Страница 8: ...pallet along with the load cell cable and product literature 1 Unpack all parts 2 Ensure each foot is screwed in until the foot touches either the load cell or the underside of the deck then unscrew e...

Страница 9: ...receptacle connector is on the short cable coming from the junction box at the top end of the scale To connect the two cables 1 Plug the pin end from the indicator cable into the receptacle end of the...

Страница 10: ...is not necessary A test weight of 25 of scale capacity recommended for this procedure Example 500 lbs for 2000 lb models 5000 lbs for 20 000 lb models 1 Remove the junction box cover and identify the...

Страница 11: ...oad the scale to near capacity two or three times 2 With no load on the scale place the indicator in calibration mode and perform a zero calibration 3 Place test weights on the platform equal to 70 80...

Страница 12: ...box as viewed from the bottom To verify correct load cell junction box terminal matching see the numbers on the terminals inside the junction box and the corner numbering diagram in Figure 4 2 Issue...

Страница 13: ...et in the junction box cover or through cable fittings in the NEMA Type 4X junction box 9 Corner correction trimming and calibration is necessary after load cell replacement Follow the instructions in...

Страница 14: ...Stainless Steel Nema 4X 1 6 14932 Screw Cap 10 32NF X 3 8 Hex Socket Button Head Alloy Steel Black Oxide 4 7 178613 Eyebolt 5 16 18NC X 1 1 8 Shank 900 lb Steel Zinc Plated 2 8 14664 1 2 20 NF Jam Nu...