2.  Installation of the Sensors

There are a number of general guidelines that should be taken into consideration
when choosing a sensor mounting location.

The placement of load sensors on all load bearing support members
ensures that the entire vessel is being weighed.

Look for hidden load bearing members such as discharge chutes supported
on the floor and cross connecting structures, such as catwalks, which can
transfer loads from adjoining stuctures. Both can cause sizable errors in the
sensors. Flexible couplings and slip joint couplings can help with these
problems.

Six equally spaced sensors should be placed in a location that is convenient
for servicing and on a mounting surface that is flat, free of paint, free of
welding seams, and away from the danger of fork lifts and trucks, as shown
in Figure 1.

Figure 1.  Sensor Location and a Typical Application Example

The RL8025 sensors will not work with double walled skirted vessels.

Содержание RL8025

Страница 1: ...70998 RL8025 Skirted Tank Structural Sensor Installation Guide...

Страница 2: ...4 5 Sensor Wiring 5 4 Insulation 5 7 Sensor Specifications 6 6 Junction Box Connections Adjustments Calibration 6 8 Limited Warranty 8 Copyright 2003 Rice Lake Weighing Systems All rights reserved Pri...

Страница 3: ...ure as shown in Figure 2 on page 3 The RL8025 is available in either alloy steel or optional stainless It should be noted that the RL8025 sensor can be used on a wide range of capacity vessels but car...

Страница 4: ...or and cross connecting structures such as catwalks which can transferloadsfromadjoiningstuctures Bothcancausesizableerrorsinthe sensors Flexible couplings and slip joint couplings can help with these...

Страница 5: ...r RLWS distributor for possible preventative measures Theloadmustalwaysbeappliedintheprimaryloadaxis Extraneousloads or compound stress must be avoided For vertical support members select a location a...

Страница 6: ...ry and flat to allow maximum gripping surface area 2 Using the sensor and the included plastic drill guides as a template drill two 5 16 holes It is normal for the plastic drill guides to spin during...

Страница 7: ...Continue until 25 ft lbs is reached 3 Connect the sensors to the junction box which should be mounted outside of the insulation for easy access Refer to the guide shown on page 6 and the labels on th...

Страница 8: ...e r G G I S e t i h W G I S e r a B r o y a r G D L E I H S 7 Sensor Specifications e g n a R p m e T p m o C F 0 5 1 0 e g n a R p m e T e f a S F 0 8 1 0 4 t u p t u O n o t c e f f E p m e T F 5 1...

Страница 9: ...ct alteration improper installa tion improper repair or improper testing RLWS shall be the sole judge of all alleged non conformities Such equipment has not been modified altered or changed by any per...

Отзывы: