background image

Rice Lake continually offers web-based video training on a growing selection 

of product-related topics at no cost. Visit www.ricelake.com/webinars.

Содержание rl-mps-30

Страница 1: ...132702 Rice Lake Mechanical Physician Scale w hand post Model RL MPS 30 Operation Instructions ...

Страница 2: ......

Страница 3: ...tient 9 6 0 Troubleshooting 9 7 0 Specifications 9 Technical training seminars are available through Rice Lake Weighing Systems Course descriptions and dates can be viewed at www ricelake com or obtained by calling 715 234 9171 and asking for the training department 2012 Rice Lake Weighing Systems All rights reserved Specifications subject to change without notice Rice Lake Weighing Systems is an ...

Страница 4: ...Rice Lake continually offers web based video training on a growing selection of product related topics at no cost Visit www ricelake com webinars ...

Страница 5: ...r through basic instructions on pillar assembly wheel installation pillar height rod installation hand post installation and the zero adjustment of the scale Figure 1 1 Mechanical Physician Scale Parts Breakdown This manual can be viewed and downloaded from the Rice Lake Weighing Systems web site at www ricelake com health Rice Lake Weighing Systems is an ISO 9001 registered company Weigh beam Poi...

Страница 6: ...rior to assembly you ll need the following tools to finish assembling the Mechanical Physician Scale Multi purpose tool included Wrench included The pillar comes separate from the scale base and must be attached prior to use Use the following steps to attach the pillar to the scale base 1 Set the scale base on a table or other convenient place 2 Remove the twisty ties off the scale base as shown o...

Страница 7: ...e base assembly ensuring that the RLWS logo located on the weight beam faces the scale base Figure 2 3 Attach the Pillar to the Scale Base 4 Using the wrench provided insert and tighten the eight bolts and washers to secure the pillar to scale base Figure 2 4 Attach Eight Bolts and Washers to Secure the Pillar to the Scale Base ...

Страница 8: ...ull the hook of the steelyard rod with the hook of the multi purpose tool to connect it to the scale base lever as shown in Figure 2 5 then push the scale base lever towards the pillar head and hook the bearing of the steelyard rod on the pivot of the long lever Visually ensure that the force lever assembly linkage is centered and properly aligned Occasionally during shipping alignment will become...

Страница 9: ...ront side of the pillar as shown in Figure 2 7 One is located at the top of the pillar and the other towards the bottom of the pillar Figure 2 7 Attach the Slotted Screw Location onto the Pillar Bolt Location 2 Use the enclosed wrench to tighten the two stainless steel hex head screws but ensure not to over tighten 3 To raise or lower the height rod press the red button at the top of the height ro...

Страница 10: ...errors 1 Align the angle iron of the wheel base to the scale platform as shown in Figure 2 9 Figure 2 9 Attach the Scale Wheels onto the Scale Base 2 Use the screws and washers that are included with the scale to fix the wheel to the platform adjusting the angle iron at a level position then tighten screws 3 When moving the scale hold the two side faces of the pillar to keep the front side of the ...

Страница 11: ...screws from the scale base and set the screws and washers aside Figure 3 1 Unscrew Hex Head Screws From Scale Platform 2 Position the hand post over the screw holes on the scale platform making sure that the washer is set between the hand post base and the screw Figure 3 2 Position Hand Post 3 Tighten all four hex head screws with the wrench that has been provided Figure 3 3 Tighten Hex Head Screw...

Страница 12: ...irmly seated in the notch and the small poise is firmly against the shoulder of the beam 3 Check the eye loop area of the scale to ensure that the scale pointer is equally balanced between the eye loop area Figure 4 1 Eye Loop Area and Zero Adjusting Screw Location 4 If the scale is not balancing properly then the small zero balance weight must be adjusted Turn the zero adjusting screw shown in Fi...

Страница 13: ...heck if the beam pointer is touching the side of the eye loop in its range of travel Visually ensure that the linkage is centered and properly aligned Occasionally during shipping the alignment will become skewed The linkage must be free floating in order for the scale to weigh properly The linkage can be seen by looking up underneath the top weigh beam if the scale is slightly tipped to one side ...

Страница 14: ...30 p m Monday through Friday and 8 a m to 12 noon on Saturday CST Telephone Sales Technical Support 800 472 6703 Canadian and Mexican Customers 800 321 6703 International 715 234 9171 Fax Fax Number 715 234 6967 Email US sales and product information at prodinfo ricelake com International non US sales and product information at intlsales ricelake com Mailing Address Rice Lake Weighing Systems 230 ...

Страница 15: ...equipment has not been modified altered or changed by any person other than RLWS or its duly authorized repair agents RLWS will have a reasonable time to repair or replace the defective equipment Buyer is responsible for shipping charges both ways In no event will RLWS be responsible for travel time or on location repairs including assembly or disassembly of equipment nor will RLWS be liable for t...

Страница 16: ...12 Mechanical Physician Scale Installation and Operation Instructions ...

Страница 17: ......

Страница 18: ...PN 132702 11 12 ...

Отзывы: