![Rice Lake REVOLUTION 682 Synergy Plus Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/rice-lake/revolution-682-synergy-plus/revolution-682-synergy-plus_technical-manual_1453947055.webp)
Configuration
© Rice Lake Weighing Systems
●
All Rights Reserved
47
4.5.7 Stream Format Menu
This section provides a flow chart and descriptions for the Stream Format menu.
Figure 4-20. Stream Format Menu
Table 4-19. Stream Format Menu Parameters
Parameter
Description
Format
Specifies the stream format used for streaming output of scale data or specifies the expected input for a serial scale;
Settings:
RLWS
(default)
–
Rice Lake Weighing Systems stream format (
Cardinal
– Cardinal stream format (
)
Weigh-Tronix
– Avery Weigh-Tronix stream format (
Toledo
– Mettler Toledo stream format (
)
Custom
– Custom stream format
Custom
Specifies the custom stream format; only displays if SFORMAT is set to CUSTOM; see
stream format tokens;
Enter characters: Alphanumeric entry up to 1,000 characters
Gross Token
Mode token when streaming the gross weight;
Enter characters: Alphanumeric entry up to 8 characters,
G
(default)
Tare Token
Mode token when streaming the tare weight;
Enter characters: Alphanumeric entry up to 8 characters,
T
(default)
Net Token
Mode token when streaming the net weight;
Enter characters: Alphanumeric entry up to 8 characters,
N
(default)
Positive Token
Polarity token when the weight is positive;
Settings:
Space
(default), None, +
Negative Token
Polarity token when the weight is negative;
Settings: Space, None,
–
(default)
Primary Token
Units token when streaming primary units;
Enter characters: Alphanumeric entry up to 8 characters,
L
(default)
Secondary Token
Units token when streaming secondary units;
Enter characters: Alphanumeric entry up to 8 characters,
K
(default)
Tertiary Token
Units token when streaming tertiary units;
Enter characters: Alphanumeric entry up to 8 characters,
K
(default)
Zero Token
Status token when the weight is at center of zero;
Enter characters: Alphanumeric entry up to 2 characters,
Z
(default)
Motion Token
Status token when the weight is in motion;
Enter characters: Alphanumeric entry up to 2 characters,
M
(default)
Out of Range Token Status token when the weight is out of range;
Enter characters: Alphanumeric entry up to 2 characters,
O
(default)
Ok Token
Status token when the weight is OK (not invalid, out-of-range, at zero or in-motion);
Enter characters: Alphanumeric entry up to 2 characters (default is a space)
Invalid Token
Status token when streaming an invalid weight;
Enter characters: Alphanumeric entry up to 2 characters,
I
(default)
Format
Custom
Tare Token
Gross Token
Invalid Token
Setup
Tare
User
Stream Format
Print Format
Setpoint
Net Token
Secondary Token
Primary Token
Negative Token
Tertiary Token
Zero Token
Positive Token
Invalid Token
Ok Token
Out of Range Token
Motion Token