680 Synergy Plus – Digital Weight Indicator
62
Visit our website
11.0 Appendix
11.1 Error Messages
The 680 indicator provides a number of error messages. When an error occurs, the message is displays on the indicator.
11.1.1 Displayed Error Messages
The 680 provides a number of front panel error messages to assist in problem diagnosis.
lists these messages and
their meanings.
11.2 ZZ EDP Command
The ZZ EDP command can be used to remotely query which annunciators are currently displayed on the indicator front panel.
The ZZ command returns a decimal number representing the LED annunciators currently lit (see
).
Example: If the annunciator status value returned on the ZZ command is 148, the gross, standstill and lb annunciators are lit.
The number 145 represents the sum of the values for the gross mode annunciator (128), the tare entered annunciator
(16) and the standstill annunciator (4).
Error Message
Description
-------
Overflow error – Weight value too large to be displayed
Gross > overload limit – Gross value exceeds overload limit; Check configuration or signal input level; Overload can
be caused by input signal > 45 mV or common mode voltage > 950 mV
vvvvvvv
Gross < underload limit – Gross value exceeds underload limit
tare in motion not allowed
Scrolls across display when attempting to perform a tare while weight is in motion, if in motion tares are not allowed
negative tare not allowed
Scrolls across display when attempting to perform a negative tare, if a negative tare is not allowed
keyed tare not allowed
Scrolls across display when attempting to perform a keyed tare, if a keyed tare is not allowed
tare larger than capacity
not allowed
Scrolls across display when attempting to perform a tare larger than capacity, if it is not allowed
tare already in system
Scrolls across display when attempting to perform a tare if a tare is already in the system, if tare is not configured to
replace or remove
initial zero failed
Scrolls across display when an attempt to perform an initial zero fails, only possible at startup
please wait
Scrolls across display when calibrating
alarm
Displays when a configured setpoint’s ALARM action occurs
Table 11-1.
680
Error Messages
Decimal Value
Annunciator
1
Net
2
Center of zero
4
Standstill
8
Keyed tare entered
16
Tare entered
32
kg/secondary units
64
lb/primary units
128
Gross
Table 11-2. Status Codes Returned on the ZZ Command