7.14 Weigh Mode Commands
These commands function in the weigh mode. Non weight related commands work in setup mode.
7.15 Batching Control Commands
The commands listed in
provide batching control through a communications port.
Command
Description
Values
CONSNUM
Returns current consecutive number value
0–9999999,
0
(default)
UID
Set unit ID
Up to 6 alphanumeric characters,
1
(default)
SD
Set or return the current system date
MMDDYY
,
DDMMYY, YYMMDD,
or
YYDDMM.
Enter six-digit date using the
year-month-day order specified for the DATEFMT parameter, using only the last two
digits of the year; The current system date is returned by only sending
SD
ST
Set or return the current system time
HHMM
(enter using 24-hour format)
The current system time is returned by only sending
ST
SX#
n
Start serial data stream(s)
OK
or
??
An EX command sent while in setup mode does not take effect until the indicator is
returned to weigh mode
EX#
n
Stop serial data stream(s)
RS
Reset system
Soft reset; Used to reset the indicator without resetting the configuration to the
factory defaults
SF#
n
Returns a single stream frame from scale n (n=1)
using the standard Rice Lake format.
--
XA#
n
Returns the accumulator value in displayed units
nnnnnnnnn UU
XAP#
n
Returns the accumulator value in primary units
XAS#
n
Returns the accumulator value in secondary units
XG#
n
Returns the gross weight in displayed units
nnnnnnnnn UU
XGP#
n
Returns the gross weight in primary units
XGS#
n
Returns the gross weight in secondary units
XN#
n
Returns the net weight in displayed units
nnnnnnnnn UU
XNP#
n
Returns the net weight in primary units
XNS#
n
Returns the net weight in secondary units
XT#
n
Returns the tare weight in displayed units
nnnnnnnnn UU
XTP#
n
Returns the tare weight in primary units
XTS#
n
Returns the tare weight in secondary units
For commands ending with
#n
, n is the scale number (1)
Table 7-14. Weigh Mode Commands
Command
Description
Values
BATSTART
Batch Start
If the BATRUN digital input is active or not assigned, the BATSTART command can be used to
start the batch program
BATSTOP
Batch Stop
Stops an active batch and turns off all associated digital outputs; Requires a Batch Start to
resume processing
BATPAUSE
Batch Pause
Pauses an active batch and turns off all digital outputs except those associated with Concurrent
and Timer setpoints; processing is suspended until the indicator receives a Batch Start signal;
pressing the BATSTRT digital input, BATSTART serial command, Batch Start softkey or the
StartBatch function (in iRite) resumes the batch and re-energizes all digital outputs turned off by
the Batch Pause
BATRESET
Batch Reset
Stops the program and resets the batch program to the first batch step; use the BATRESET
command after making changes to the batch configuration
BATSTATUS
Batch Status
Returns
XYYY
where
X
is
S
(if the batch is stopped),
P
(if the batch is paused),
R
(if the batch is running); and
YYY
is the setpoint number the batch is currently on (1-8)
Table 7-15. Batching Control Commands