Rice Lake MSI Dyna-Clamp Скачать руководство пользователя страница 6

MSI Dyna-Clamp Tension Meter

2

Visit our website 

www.RiceLake.com

1.2 Display

The front panel consists of a two-line, LCD display with four LED annunciators and four keys. This section provides a detailed 

description of what is featured on the display and the key functions.

Figure 1-1. Dyna-Clamp Front Panel

Wire Rope Examples:

Below are two examples of how wire rope types appear on the Dyna-Clamp display. The diameter of the wire rope type displays 

first, followed by the wire rope class.

Wire Rope Diameter = 

3/4''

 | Wire Rope Class = 

6x36

Wire Rope Diameter = 

1/2''

 | Wire Rope Class = 

8x19

Item No.

Description

1

Power Key – powers the Dyna-Clamp on and off; in setup mode, it returns the unit to tension display without saving settings

2

Zero Key– zeros out the residual tension on the link; in setup mode, it saves settings and drops back one menu level

3

F1 Key – programmable to user functions (

Section 3.3 on page 7

)

4

F2 Key – programmable to user functions (

Section 3.3 on page 7

)

5

Low Battery – displays when approximately 10% of battery life remains and blinks when automatic shutdown is imminent

6

Primary display with six 0.7'' (18 mm) numeric digits; displays live wire rope tension and is sunlight visible

7

Secondary display with eight 0.5'' (13mm) numeric digits; displays wire rope diameter, average tension and peak tension

8

Average Function – indicates the average function is currently displaying on the secondary (top) display line; displays the 

running average tension measurement (

Section 2.7 on page 5

)

9

Peak Function – indicates the peak function is currently displaying on the secondary (top) display line; displays the greatest 

tension that has been measured (

Section 2.8 on page 5

)

10

Kilonewton – indicates the tension display is in kilonewtons

11

Pound-force – indicates the tension display is in pounds

12

Kilogram-force – indicates the tension display is in kilograms

13

Setpoint/Range LEDs – indicates if tension measurements are outside of the programmable range

14

F-Key LEDs – not currently supported

Table 1-1.  Key Descriptions

MSI DYNA-CLAMP

USER KEYS

ZERO

POWER

F1

F2

Measurement Systems
International

F1

F2

SETPOINTS

1

2

14

13

8
9

10
11
12

1

2

3

4

7

6

5

Содержание MSI Dyna-Clamp

Страница 1: ...MSI Dyna Clamp Tension Meter Operation Manual May 19 2020 PN 193853 Rev A...

Страница 2: ...marks of their respective companies All information contained within this publication is to the best of our knowledge complete and accurate at the time of publication Rice Lake Weighing Systems reserv...

Страница 3: ...sion Measurement 4 2 7 Average Function 5 2 7 1 Average Procedure 5 2 7 2 Clearing Average 5 2 8 Peak Function 5 2 8 1 Clearing Peak 5 2 9 Safety Strap 5 2 10 Carry Case Option 5 3 0 Configuration 6 3...

Страница 4: ...na Clamp Tension Meter ii Visit our website www RiceLake com Rice Lake continually offers web based video training on a growing selection of product related topics at no cost Visit www ricelake com we...

Страница 5: ...nderstood Failure to follow the instructions or heed the warnings could result in injury or death Contact any Rice Lake Weighing Systems dealer for replacement manuals Failure to heed could result in...

Страница 6: ...Battery displays when approximately 10 of battery life remains and blinks when automatic shutdown is imminent 6 Primary display with six 0 7 18 mm numeric digits displays live wire rope tension and is...

Страница 7: ...n extended period of time 2 2 Product Dimensions Figure 2 1 Product Diagram 2 3 Power Press to turn on the Dyna Clamp The startup sequence displays all LCD segments followed briefly by the software ve...

Страница 8: ...y grease to the drive rod threads to maintain proper lubrication 1 Loosen the drive rod 2 Zero the Dyna Clamp Section 2 5 Figure 2 2 Dyna Clamp On Wire Rope 3 Position the Dyna Clamp on the wire rope...

Страница 9: ...Clearing Average Follow this procedure when the running average needs to be cleared 1 Position the Dyna Clamp on the wire rope and tighten slightly so a little positive tension is measured by the dev...

Страница 10: ...ls through the available wire rope types and the average and peak values in the secondary top display area Section 3 3 4 on page 7 ActFun performs action based on the active function that is displayed...

Страница 11: ...counting from to followed by the c cal value displaying in the secondary display area The test can be single stepped 1 Press F key set to then immediately press to stop the auto scroll 2 Press to scro...

Страница 12: ...gh setpoint value then the setpoint 2 LED turns on If the tension measurement is within the specified range then neither setpoint LED is on Use the following steps to set the Range setpoint values 1 P...

Страница 13: ...s in the secondary top display area 4 Press to scroll through the available filter settings 5 With desired filter displayed press to accept displays 6 Press to save and return to tension mode 3 7 Unit...

Страница 14: ...if it is in the setup menu The auto off parameter Section 3 4 on page 8 also conserves battery life by turning the unit off if no activity is sensed for a set time The standard mode is recommended for...

Страница 15: ...before load is lifted Zero the Dyna Clamp with no load attached lbf kgf kN units causing confusion Select proper units Requires recalibration Requires authorized service Display reading not stable Exc...

Страница 16: ...ls are recharged immediately after Low Battery starts to blink Do not allow the batteries to discharge completely it may compromise the recharge life of the battery NiMH Cells have a lower capacity th...

Страница 17: ...4 Bobbin Replacement 1 Remove the bolt securing the wire rope bobbin to the frame and discard old bobbin 2 Align new wire rope bobbin with hole in frame 3 Torque bolt to 30 ft lb 40 N m with blue Loc...

Страница 18: ...c digits Secondary Display top Eight 0 5 13 mm numeric digits Function Keys Programmable Keys Two user programmable F1 F2 TEST UNIT PRINT SCROLL ACTFUN Permanent Keys Two fixed POWER ZERO Setpoints Tw...

Страница 19: ......

Страница 20: ...anada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 Rice Lake Weighing Systems is an ISO 9001 registered company Rice Lake Weighing Systems Specifications subject to change wi...

Отзывы: