4.1.4 View Total
F-key activates total weight display followed by the number of samples. With the Total weight displays press
ZERO
to clear.
4.1.5 Net / Gross
Switches the display between net and gross modes. Net weight is defined as gross weight minus a tare weight.
To switch between net mode and gross mode, press the F-key (set to net/gross function). This will only work if a tare value has
been established.
The operator can switch back to gross from net without clearing the tare value. Only clearing or setting a new tare will change
the tare value held before switching into gross mode.
OIML Legal for Trade units only: The
NET/GROSS
key is a temporary action only. The gross weight displays for two seconds
and then the display returns to the net mode. The only way to return to permanent gross readings is to clear the tare. See
.
4.1.6 Peak Hold
Peak hold will only update the display when a higher peak weight reading is established.
The peak hold function uses a high speed mode of the A/D converter allowing it to capture transient weights at a far higher rate
than typical scales. Peak hold is cleared and re-enabled with the F-key.
Peak hold is not available on NTEP or OIML Legal for Trade certified scales.
4.1.7 Units
Units can be changed in two ways.
• Program a user function key to units
• Change the units with the
Setup
menu using the following steps
Unit switching is not available on OIML certified Legal for Trade scales.
4.1.8 High Resolution Test Mode
High Resolution Test Mode displays weight at x10 resolution.
1. Program the
to
hI-rES
(
).
2. Press
to toggle between normal and x10 resolution display.
All annunciators flash to indicate that the weight display is in x10 resolution test mode and not set to the approved legal-for-
trade resolution.
In some cases, the displayed weight in high resolution test mode will require six digits to fully display. In these cases, only the
five least significant digits will be displayed. The full weight can be displayed in normal resolution by pressing the function
button.
Ex: 1000.02 kg will display as 000.02 kg.
High resolution test mode is for scale service and diagnostic use only.
Increasing the scale display resolution beyond the calibrated value does not increase scale accuracy.
High resolution test mode is not available in HB-44 and R-76 standards.