17. This should save loading weights on all eight scales.

Figure 7. Set Gravity Value

18. Enter the gravity value for the area the wheel weigh pads are to be used in.
19. Press 

.

20. Press 

 three times to get back to the 

Technical Setup

 menu.

Figure 8. Technical Setup Menu

21. Press 

. Setup changed box displays.

Figure 9. Setup Changed

22. Press 

 to save settings and complete setup. Indicator reboots to 

Weigh

 mode.

Initial Setup Parameters

The following parameter windows display during initial setup before the indicator reboots to 

Weigh

 mode.

• The 

Backup of the Configuration

 window — Press 

 to backup all settings

• The 

Password

 window displays — Press 

 or 

, depending if a password is needed

• The 

Technical Setup

 window displays — Press 

 to convert the indicator units to match the weigh pad units

Gravity value setting

1

Esc

2

/

3

4

5

*

6

7

BkSp

8

-

9

C

OK

0

+

9.75001 

~

 9.84999

9.8O39O

OK

Esc

Calibration

F1

First Programming

F2

AF08 functions

F3

Generic functions

F4

Shortcuts

F5

Databases

F6

Technical setup (INTERNAL USE ONLY)

1/3

Esc

Setup changed.

Save changes before restart the

indicator?

Technical setup

Cancel

Yes

No

Yes

Yes

Yes

No

Yes

Содержание Load Ranger

Страница 1: ... the ID settings 5 Press or to increase or decrease the selected digit and press to move between the digits to enter the pad ID number The first Pad ID number must be 01 and the remaining pad ID numbers must increment in ascending numeric order Example 01 02 03 etc 6 Press to confirm displays 7 Press to enter the Bluetooth Initialization menu displays 8 Press to confirm displays followed by displa...

Страница 2: ...e screen when the logo displays to enter the Technical Setup menu Figure 2 Touch Upper Right Corner of the Display 3 Press 4 Press 5 Press Figure 3 Select Scales 6 Select the number of wheel weigh pads to be used 7 Press 8 Press 9 Press Calibration F1 Scale selection F1 1 scale s Number of scales F1 1 1 F1 2 F2 3 F3 4 F4 5 F5 6 F6 Number of scales 1 3 Cancel OK OK WWS configuration F1 WWS pairing ...

Страница 3: ... 14 Once the serial number of the first wheel weigh pad displays turn on the second wheel weigh pad assigned ID 02 Figure 5 Pairing 15 Repeat this process until all of the weigh pad pin numbers in the desired system are displayed Once the last wheel weigh pad is paired a prompt displays Figure 6 Pairing Successful 16 Press to confirm the completion of pairing The Gravity Value Setting keyboard dis...

Страница 4: ...ters The following parameter windows display during initial setup before the indicator reboots to Weigh mode The Backup of the Configuration window Press to backup all settings The Password window displays Press or depending if a password is needed The Technical Setup window displays Press to convert the indicator units to match the weigh pad units Gravity value setting 1 Esc 2 3 4 5 6 7 BkSp 8 9 ...

Страница 5: ...on the Ai 1 indicator The pad ID assigned within the weigh pad dictates the scale number and it does not need to match the Ai 1 indicator channel number 6 Turn on all of the weigh pads 7 Turn on the Ai 1 indicator briefly displays on weigh pads represents the assigned pad ID number then displays on the weigh pads and they are ready for use Wired Setup A wired system allows for weighing up to four ...

Страница 6: ... 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 Rice Lake Weighing Systems is an ISO 9001 registered company Rice Lake Weighing Systems Specifications subject to change without notice www ricelake com Load Ranger Wheel Weigh Pads PN 189611 Rev B February 22 2021 ...

Отзывы: