Weighing Operations
The illustration below shows the IQ plus 590-DC keypad and normal mode key functions.
Basic IQ plus 590-DC weighing operations are
summarized below:
Toggle Gross/Net/Piece Count Mode
Press the
GROSS/NET
key to switch the display mode
between gross, net, and piece count modes. If a tare
value has been entered or acquired, the net value is the
gross weight minus the tare. If access to piece count
mode is disabled, pressing the
GROSS/NET
key
switches between gross and net modes only.
Gross mode is shown by the
G
annunciator; net mode
is shown by the
N
annunciator. Piece count mode is
shown by the LCD annunciator adjacent to the
PC
at
the right edge of the display.
Toggle Units
Press the
UNITS
key to switch between primary and
secondary units. The units annunciator arrow on the
right side of the LCD display points to the units
identifier.
Zero Scale
1. In gross mode, remove all weight from the
scale and wait for the standstill annunciator
(
).
2. Press the
ZERO
key. The center of zero
(
) annunciator lights to indicate the
scale is zeroed.
Acquire Tare
1. Place container on scale and wait for the
standstill annunciator (
).
2. Press the
TARE
key to acquire the tare weight
of the container.
3. Net weight is displayed and the
annunciator lights to show the tare value was
acquired.
Enter Tare (Keyed Tare)
1. Use the numeric keypad to enter the tare
value, then press the
TARE
key.
2. Net weight is displayed and the
annunciator lit to show the tare value was
entered.
Remove Stored Tare Value
1. Remove all weight from the scale and wait for
the standstill annunciator (
).
2. Press the
TARE
key. The
annunciator goes
off, indicating the tare value has been
removed.
Indicators with the REGULA parameter set to
NONE or NTEP can clear a stored tare value
using the following procedure:
1. Press
DISPLAY TARE
to show the stored tare
value.
2. Press the
CLEAR
key twice to remove the
stored tare.
Print Ticket
1. Wait for the standstill annunciator (
).
2. Press the
key to send weight data to
the serial port.
T
4
9
0
8
5
2
7
6
3
CLEAR
DISPLAY
TARE
ZERO
GROSS
NET
TARE
UNITS
B/N
Units
POWER
ENTER
SAMPLE
MODE
I / O
Switch between
primary and
secondary units
Send data to
serial port
Set gross weight
to zero
Switch between
gross, net, and
piece count mode
Acquire tare
NORMAL MODE KEY FUNCTIONS
Display current
tare weight
Power on/off
T