Commands
9
Print Request
Command: 20, 0x014
Parameter: Scale number
Command 20 causes the indicator to execute a print
command for the current scale.
Display Accumulator
Command: 21, 0x015
Parameter: Scale number
Command 21 causes the value of the accumulator for
the specified scale to be displayed and returned. This
command is only valid if the accumulator for the
specified scale is enabled.
Clear Accumulator
Command: 22, 0x016
Parameter: Scale number
Command 22 clears the value of the accumulator for
the specified scale. This command is only valid if the
accumulator for the specified scale is enabled.
Push Weight to Accumulator
Command: 23, 0x017
Parameter: Scale number
Command 23 adds the net weight on the specified
scale to the value of the accumulator for the specified
scale. The scale must return to net zero between
accumulations. The indicator returns the accumulated
weight data for the specified scale. This command is
only valid if the accumulator for the specified scale is
enabled.
Return Gross as Integer
Command: 32, 0x020
Parameter: Scale number
Command 32 returns the gross weight value for the
specified scale as an integer.
Return Net as Integer
Command: 33, 0x021
Parameter: Scale number
Command 33 returns the net weight value for the
specified scale as an integer.
Return Tare as Integer
Command: 34, 0x022
Parameter: Scale number
Command 34 returns the tare weight value for the
specified scale as an integer.
Return Piece Count
Command: 35, 0x023
Parameter: Scale number
Command 35 returns the piece count value for the
specified scale. This command is valid only for the
520
indicator, and only if count mode is enabled.
Return Current Display as Integer
Command: 37, 0x025
Parameter: Scale number
Command 37 returns the weight value for the
specified scale as currently displayed. This may
include gross, net, tare, piece count, or accumulator
values, as enabled. On the
920i
, the weight value is
returned in the mode used to display a scale widget.
Return Accumulator as Integer
Command: 38, 0x026
Parameter: Scale number
Command 38 returns the accumulator value for the
specified scale. This command is only valid if the
accumulator for the specified scale is enabled.
Return Rate of Change as Integer
Command: 39, 0x027
Parameter: Scale number
Command 39 returns the current rate of change value
for the specified scale. This command is valid only for
the
920i
.
Return Peak as Integer
Command: 40, 0x028
Parameter: Scale number
Command 40 returns the net peak value for the
specified scale. This command is valid only for the
520
indicator, and only if the peak hold function is
enabled.
Set Batching State
Command: 95, 0x05F
Parameter: State (0 = off; 1 = auto; 2 = manual)
C o m m a n d 9 5 s e t s t h e b a t c h i n g ( B AT C H N G )
parameter. Indicator status is returned with the current
weight for the last scale specified.