background image

DeviceNet Interface Specifications

15

DeviceNet Interface Limited Warranty

Rice Lake Weighing Systems (RLWS) warrants that all RLWS equipment and systems properly installed by a 
Distributor or Original Equipment Manufacturer (OEM) will operate per written specifications as confirmed by the 
Distributor/OEM and accepted by RLWS. All systems and components are warranted against defects in materials 
and workmanship for one year. 

RLWS warrants that the equipment sold hereunder will conform to the current written specifications authorized by 
RLWS. RLWS warrants the equipment against faulty workmanship and defective materials. If any equipment fails 
to conform to these warranties, RLWS will, at its option, repair or replace such goods returned within the warranty 
period subject to the following conditions:

Upon discovery by Buyer of such nonconformity, RLWS will be given prompt written notice with a 
detailed explanation of the alleged deficiencies.

Individual electronic components returned to RLWS for warranty purposes must be packaged to 
prevent electrostatic discharge (ESD) damage in shipment. Packaging requirements are listed in a 
publication, “Protecting Your Components From Static Damage in Shipment,” available from RLWS 
Equipment Return Department.

Examination of such equipment by RLWS confirms that the nonconformity actually exists, and was 
not caused by accident, misuse, neglect, alteration, improper installation, improper repair or improper 
testing; RLWS shall be the sole judge of all alleged non-conformities.

Such equipment has not been modified, altered, or changed by any person other than RLWS or its duly 
authorized repair agents.

RLWS will have a reasonable time to repair or replace the defective equipment. Buyer is responsible 
for shipping charges both ways.

In no event will RLWS be responsible for travel time or on-location repairs, including assembly or 
disassembly of equipment, nor will RLWS be liable for the cost of any repairs made by others.

T

HESE

 

WARRANTIES

 

EXCLUDE

 

ALL

 

OTHER

 

WARRANTIES

EXPRESSED

 

OR

 

IMPLIED

INCLUDING

 

WITHOUT

 

LIMITATION

 

WARRANTIES

 

OF

 

MERCHANTABILITY

 

OR

 

FITNESS

 

FOR

 

A

 

PARTICULAR

 

PURPOSE

. N

EITHER

 RLWS 

NOR

 

DISTRIBUTOR

 

WILL

IN

 

ANY

 

EVENT

BE

 

LIABLE

 

FOR

 

INCIDENTAL

 

OR

 

CONSEQUENTIAL

 

DAMAGES

RLWS 

AND

 

BUYER

 

AGREE

 

THAT

 RLWS’ 

SOLE

 

AND

 

EXCLUSIVE

 

LIABILITY

 

HEREUNDER

 

IS

 

LIMITED

 

TO

 

REPAIR

 

OR

 

REPLACEMENT

 

OF

 

SUCH

 

GOODS

. I

N

 

ACCEPTING

 

THIS

 

WARRANTY

THE

 

BUYER

 

WAIVES

 

ANY

 

AND

 

ALL

 

OTHER

 

CLAIMS

 

TO

 

WARRANTY

.

S

HOULD

 

THE

 

SELLER

 

BE

 

OTHER

 

THAN

 RLWS, 

THE

 

BUYER

 

AGREES

 

TO

 

LOOK

 

ONLY

 

TO

 

THE

 

SELLER

 

FOR

 

WARRANTY

 

CLAIMS

.

N

O

 

TERMS

CONDITIONS

UNDERSTANDING

OR

 

AGREEMENTS

 

PURPORTING

 

TO

 

MODIFY

 

THE

 

TERMS

 

OF

 

THIS

 

WARRANTY

 

SHALL

 

HAVE

 

ANY

 

LEGAL

 

EFFECT

 

UNLESS

 

MADE

 

IN

 

WRITING

 

AND

 

SIGNED

 

BY

 

A

 

CORPORATE

 

OFFICER

 

OF

 RLWS 

AND

 

THE

 B

UYER

.

© 2010 Rice Lake Weighing Systems, Inc. Rice Lake, WI USA. All Rights Reserved.

RICE LAKE WEIGHING SYSTEMS • 230 WEST COLEMAN STREET • RICE LAKE, WISCONSIN 54868 • USA

Содержание DeviceNet Series

Страница 1: ...69949 Rev A DeviceNet Interface for 520 720i 820i and 920i Indicators Installation and Programming Manual...

Страница 2: ......

Страница 3: ...Net Key Press toggle mode 9 Zero 9 Display Tare 9 Enter Tare integer 9 Acquire Tare simulate TARE key press 9 Clear Tare 9 Primary Units 9 Secondary Units 9 Tertiary Units 9 Units Key Press toggle uni...

Страница 4: ...eight as Float 12 Read Tare as Float 12 Read Piece Count as Float 12 Read Current Display as Float 12 Read Accumulator as Float 12 Read Rate of Change as Float 12 Read Peak Value as Float 12 Set Setpo...

Страница 5: ...w ricelake com 1 0 Introduction The DeviceNet Interface returns weight and status information from a 520 720i 820i or 920i indicator to a master controller and provides limited control of indicator fu...

Страница 6: ...or models with backplates place indicator face down on an antistatic work mat Remove screws that hold the backplate to the enclosure body Use a wrist strap to ground yourself and protect components fr...

Страница 7: ...rap to ground yourself and protect components from electrostatic discharge ESD when working inside the indicator enclosure 3 Carefully align the large option card connector with connector J2 on the CP...

Страница 8: ...SHIELD Cable shield Bare CAN_L CAN_L bus line Light blue V Negative supply Black 2 3 DIP Switch Configuration A DIP switch is used to configure the DeviceNet network baud rate and node address Figure...

Страница 9: ...FF OFF ON ON OFF OFF 44 54 ON OFF ON ON OFF OFF 13 15 OFF OFF ON ON OFF ON 45 55 ON OFF ON ON OFF ON 14 16 OFF OFF ON ON ON OFF 46 56 ON OFF ON ON ON OFF 15 17 OFF OFF ON ON ON ON 47 57 ON OFF ON ON O...

Страница 10: ...2 Network Status Off Not powered or not online Steady Red Critical link failure Flashing Red Connection time out Flashing Green Online not connected Steady Green Online connected LED 3 Module Status...

Страница 11: ...ation Decimal Hex Command 0 0x000 Return Status and Weight integer 1 0x001 Display Channel 2 0x002 Display Gross Weight 3 0x003 Display Net Weight 4 0x004 Display Count 9 0x009 Gross Net key press tog...

Страница 12: ...place of the low byte see Table 3 5 Setpoint commands return batch status in the low byte of the status word and the setpoint number in the high byte Table 3 4 Indicator Status Data Format Word 2 Bit...

Страница 13: ...current scale Display Tare Command 11 0x00B Parameter Scale number Command 11 causes the tare weight on the specified scale to be displayed If a scale number other than 0 is specified the indicator fi...

Страница 14: ...ter Scale number Command 33 returns the net weight value for the specified scale as an integer Return Tare as Integer Command 34 0x022 Parameter Scale number Command 34 returns the tare weight value f...

Страница 15: ...r Slot number Value Bit number Command 115 sets the specified digital output OFF inactive Use slot number 0 for onboard digital outputs Indicator status is returned with the current weight for the las...

Страница 16: ...scale in floating point format This command is only valid for the 820i or 920i Read Peak Value as Float Command 296 0x128 Parameter Scale number Command 296 returns the net peak value for the specifie...

Страница 17: ...e setpoint is enabled and requires a bandwidth value Read Setpoint Preact as Float Command 323 0x143 Parameter Setpoint number Command 323 returns the preact value for the specified setpoint in floati...

Страница 18: ...Current TRMS 28 9mA 920i Power TRMS 2 18 W Current TRMS 28 9 mA Communications Specifications DeviceNet Network Communications Twisted pair cabling at 125 250 or 500 Kbps Update rate is dependent on...

Страница 19: ...d was not caused by accident misuse neglect alteration improper installation improper repair or improper testing RLWS shall be the sole judge of all alleged non conformities Such equipment has not bee...

Страница 20: ...16 520 820i 920i DeviceNet Installation and Programming Manual...

Страница 21: ...Rice Lake Weighing Systems August 7 2013 PN 69949 Rev A...

Отзывы: